Important note about charging the capacitor
This capacitor must be charged BEFORE connecting the POWER and GROUND cable to the capacitor.
Failure to charge the capacitor will result in a large spark generated form the rapid inflow of current which can be very dangerous.
Electrical connections for CAP18 or CAP30
Make all wiring connections as shown in the diagram, but do not attach the
incoming positive cable to the capacitor positive terminal.
Connect the positive terminal only after following the instructions for charging the capacitor on page 8.
CAP8 • CAP18 • CAP30 User’s Manual - page 6