48
If the lamp fails to come on and the lamp monitor on the projector light is orange, you must replace the bulb.
¡For continued safety, replace with a lamp assembly of the same type.
¡Allow the projector to cool for at least 45 minutes before you open the lamp cover. The inside of the
projector can become very hot.
¡Do not drop the lamp module or touch the glass bulb ! The glass can shatter and cause injury.
Follow these steps to replace the lamp assembly.
1. Turn off the projector and allow the projector to cool thoroughly.
2. Disconnect the AC cord from the projector.
3. Remove screw with a screwdriver and disconnect the lamp cover.
4. Remove 2 screws with a screwdriver and pull out the lamp assembly by
grasping the handle.
5. Replace the lamp assembly.
6. Tighten 3 screws to secure the lamp cover to the lamp assembly.
7. Connect the detachable AC cord to the projector.
LAMP REPLACEMENT
8. Reset the lamp replacement monitor timer. (See LAMP AGE section on page 46.)
NOTE: Do not reset the LAMP REPLACEMENT MONITOR TIMER, except after the lamp is replaced.
LAMP REPLACEMENT
INDICATOR
LAMP
ASSEMBLY
HANDLE
LAMP COVER

ORDER REPLACEMENT LAMP

Replacement Lamp can be ordered through Boxlight Corporation at 1-800-762-5757 or 360-779-7901. When ordering the
Lamp, give the following information to the dealer.
Model No. of your projector : Boxlight MP-25t
Replacement Lamp Type No. : POA-LMP18J
(Service Parts No. 610 279 5417)