BOXLIGHT MP-93i specifications Control signal terminal, Mouse emulation

Models: MP-93i

1 32
Download 32 pages 54.71 Kb
Page 22
Image 22
Connection to the control signal terminal

Connection to the control signal terminal

1. Control signal terminal

Pin No.

RS-232C

 

Mouse

 

 

 

 

PS/2

ADB

Serial

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

2

 

CLK

 

 

 

 

 

 

 

3

 

DATA

DATA

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

6

SELO

SELO

 

SELO

 

 

 

 

 

7

RTS

RTS

RTS

RTS

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

9

 

+5V

+5V

 

 

 

 

 

 

10

GND

GND

GND

GND

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

13

RDP

 

 

 

 

 

 

 

 

14

TDP

 

 

TD

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

1 5

610

11 15

D-sub 15pin shrink terminal (Male)

Caution

Turn off the power of both the projector and computer before connecting.

Connect the computer to the control terminal of the projector using an appropriate cable.

 

 

Refer to the instruction manual of each device before connecting.

2.Mouse emulation

(1)Connect the projector and the mouse terminal of computer using an appropriate cable, while the projector and the computer are turn off.

(2)Turn the main power switch of the projector on and press the STANDBY/ON button. The indicator will light. (The ON indicator will light up green.).

(3)Press the INPUT of the projector or RGB button of the remote control transmitter and select the input connection.

(4)Turn on the computer.

(5)Start mouse emulation mode.

If can not start mouse emulation, reset the computer. (With soft reset or reset switch)

(6)See on the page 9 about to operate the remote control transmitter.

Caution : Mouse cannot be operated while start up screen or menu screen is being displayed.

Caution

• In some note computers which have internal pointing device, mouse emulation don't work

without setting the internal pointing device disabled. In this case, set the internal pointing

 

 

device disabled in BIOS setting. After setting in BIOS, operate (1) ~ (5) Please check its

 

hardware manuals to disable internal pointing device in BIOS setting.

In some computers, mouse emulation don't work without the utility program. In this case, see and check the operating manuals of the computer.