INSTALLATION & OPERATING INSTRUCTION MANUAL
COMMERCIAL ELECTRIC WATER HEATER
CONGRATULATIONS
GPH Recovery Capacities
TABLE OF CONTENTS
Amperage Chart
Thermostat Adjustment
DANGER
GENERAL INFORMATION
General Information continued
INSTALLATION
Locating The Water Heater
Water Connections
BEING CERTAIN IT IS FILLED WITH WATER
Water Connections continued
For protection against excessive temperatures and pressure, install temperature and pressure protective equipment required by local codes, but not less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials, as meeting the Requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22, and the Standard CAN1-4.4 Temperature, Pressure, Temperature and Pressure Relief Valves and Vacuum Relief Valves. The combination temperature and pressure relief valve must be marked with a maximum set pressure, not to exceed the maximum working pressure of the water heater. The combination temperature and pressure relief valve shall also have an hourly rated temperature steam BTU discharge capacity not less than the hourly input rating of the water heater
Hydrogen gas can be produced in a hot water system served by this water heater that has not been used for a long period of time generally two weeks or more. Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system. If hydrogen is present, there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow. There should be no smoking or open flame near the faucet at the time it is open
Water Connections continued
Dual Temperature System With Mixing Valve
Single Installation With Storage Tank Gravity Circulation
Dual Water Heater Installation
Water Connections continued
Heating Elements
Amperage Chart
Electrical Connections
A Open cover door of the control box
GENERAL OPERATION
Recovery Computation Formula
GPH Recovery Capacities
GPH= watts x 3.412 / 8.25 x Temp. Rise
Thermostat Adjustment
Thermostat Adjustment continued
DANGER
MAINTENANCE
1. Annually, check the operation of the thermostats
WARNING! THIS WATER MAY BE HOT
Complete the following information and retain for future reference