41
Condensation does not mean your tank is leaking. Most of reported tank leaks on installation are proven to be condensation. To
avoid unnecessary inconvenience and expense, make sure the tank is leaking before calling an independent servicing contractor or
qualified service professional.
If the water heater is to remain idle for 30 days or more or is subjected to freezing temperatures while shut off, the water heater and
piping should be fully drained and the drain valve should be left fully open. Refer to the “General Operation” section of this
Installation and Operating Instructions Manual for the procedure on draining the water heater.
WARNING
If the water heater display does not show “Operational” in the “Status” indicator, there may be an operating malfunction with
the water heater. If this is the case, a numeric code will be displayed. Refer to the label next to the display for the definition of
the error code and call your plumbing professional or service agent to service the water heater. Do not try to reset the water
heater without having a qualified service person to diagnose and correct the problem. If the display is blank or does not show
an error code, make sure there is power to the water heater.
Setting the water temperature to the maximum set point can result in scalding hot water delivered to the faucets. It is highly
recommended that the maximum setpoint be adjusted to the lowest temperature possible for the needs of the installation. See
following section to change the maximum setpoint limit (max setpoint). Make sure the water heater control display is not in a
public area that can result in the temperature settings being improperly adjusted. See previous warning on scalds and an ASSE
approved mixing valve.
NOTICE
When the maximum setpoint is reached, the display will show “Max Setpoint” without the setpoint value. The maximum
setting is equal to approximately 180˚F (82˚C).
The default temperature setpoint from the factory is 70˚F (21˚C).
SELECT SET
Status
Set button
Select button
Temperature
Down Button
Temperature
Up Button
°F
idle
setpoint
Operational
Sequence o
f
operation Indicato
r
Reads "Idle” or “Heating"
Status Indicato
r
Read "Operational"
or "Service Needed"
Shown flashing
in display only when
temp is adjusted
Temperature Setpoint
in Degrees F or Degrees C
Range 70 - Max °F
Range 21 - Max °C
Water Heater Display and Control Buttons