Residential Atmospheric Vent Gas Water Heater
Manufactured Home Energy Saver Models |
|
| Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed | |||||||||||||||
NATURAL GAS AND LIQUID PROPANE GAS |
|
|
|
|
|
|
|
| 77% Recovery Efficiency |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Model | Capacity |
|
|
| Recovery |
| A | B | C | D | E | F | G | H | K | Approx. | ||
|
|
| 90°F Rise* |
| Floor to | Jacket | Vent | Floor to | Floor to | Floor to | Floor to | Floor to | Depth | Shipping | ||||
Number |
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
| Flue | Dia. | Size | T&P | Gas | Cold | Hot | Heater |
| Weight | |
|
|
|
| LP |
|
|
|
|
| |||||||||
|
|
| Nat. | Nat. | Nat. | LP | LP | Conn. |
|
| Conn. | Conn. | Water | Water | Top |
|
| |
| U.S. Imp. | BTU/Hr. BTU/Hr. | U.S. | Imp. | U.S. | Imp. | in. | in. | in. | in. | in. | Conn. | Conn. | in. | in. | lbs. | ||
| Gal. Gal. | Input | Input | GPH | GPH | GPH | GPH | in. | in. | |||||||||
30 | 25 | 32,000 | 32,000 | 33 | 28 | 33 | 28 | 591/8 | 16 | 3x4 | 50 | 13 | 221/4 | 571/2 | 563/8 | 20 | 104 | |
40 | 33 | 34,000 | 34,000 | 35 | 30 | 35 | 30 | 593/8 | 18 | 3x4 | 50 | 13 | 221/4 | 573/4 | 565/8 | 22 | 120 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Model | Capacity |
|
|
| Recovery |
| A | B | C | D | E | F | G | H | K | Approx. | ||
|
|
| 50°C Rise* |
| Floor to | Jacket | Vent | Floor to | Floor to | Floor to | Floor to | Floor to | Depth | Shipping | ||||
Number |
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
| Flue | Dia. | Size | T&P | Gas | Cold | Hot | Heater |
| Weight | |
|
|
|
| LP |
|
|
|
|
| |||||||||
|
|
| Nat. | Nat. | LP |
| Conn. |
|
| Conn. | Conn. | Water | Water | Top |
|
| ||
| Liters | kW | kW | Liters/ | Liters/ | mm. | mm. | mm. | mm. | mm. | Conn. | Conn. | mm. | mm. | kg. | |||
| Input | Input | Hour | Hour | mm. | mm. | ||||||||||||
114 | 9.4 | 9.4 | 125 | 125 | 1502 | 406 | 76x102 | 1270 | 330 | 565 | 1460 | 1432 | 508 | 47 | ||||
151 | 10.0 | 10.0 | 132 | 132 | 1508 | 457 | 76x102 | 1270 | 330 | 565 | 1467 | 1465 | 558 | 54 |
To order a natural gas heater change suffix "X" to "N". For 10 year models, change suffix from “6” to “10”. *Based on manufacturers rated recovery efficiency.
| Optional Roof Jack Kits |
|
|
|
| |
|
|
| Through The Roof |
|
|
|
Part Number | A | B | Clearance |
|
|
|
|
|
| ||||
15" | 12" |
|
|
| ||
331/2" | 18" / 32" |
|
|
| ||
32" / 60" | K | |||||
48" / 90" |
|
|
|
(Includes roof jack, hardware, instructions)
B
ANODE
C
D A
9"
4" |
5" |
3" |
22.5° Max.
A
B
7"
11 5/8" |
Square |
6 1/2" |
G H
E
F
The water heater enclosure access door must be on the outside wall of the manufactured home (mobile home) only. Access to the water heater enclosure from the inside of the manufactured home (mobile home) is not permitted. The CSA International (formerly AGA/CGA) listing of this water heater includes the field installation of the following components: roof jack, and heater tie down materials. These components for field installation are shipped in a separate box from the heater and must be installed according to instructions. No other components are approved for use with the water heater. The water heater must be installed in accordance with The Federal Manufactured Home Construction and Safety Standard Title 24 CRF, Part 3280.
Meets NAECA Requirements.
General
All gas water heaters are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working pressure. All water connections are 3⁄4" NPT (19mm), all gas connections are 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), ANSI
Designed in accordance with the H.U.D. Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280.707 (d)(2) for energy efficiency.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales
International: Telephone
Sales / Technical Support
©2007, Bradford White Corporation. All rights reserved.