Bradley Smoker E19-310DC Installation, Supplies Required, Secure base to floor, piping

Models: E19-310DC

1 5
Download 5 pages 40.07 Kb
Page 3
Image 3
Installation
Figure 1

Installation

E19-310DC

Installation

 

Ø 273mm

 

Supplies Required:

 

(10-3/4")

 

 

 

247mm

• (3) M10 floor anchors and bolts

 

 

(9-3/4")

 

 

 

Teflon tape and pipe sealant

 

 

Ø 229mm (9") Flange

• Piping to 1-1/4" BSP water supply inlet on unit

 

 

with (3) Ø 10mm (3/8")

 

 

Holes on Ø 203mm (8")

Adequate supply pipe supports

 

 

Bolt Circle

 

 

 

• Piping to 1-1/4" BSP drain outlet for eyewash

 

267mm

 

Minimum 102mm (4") drain to accommodate

 

 

 

(10-1/2")

 

 

115 liters (30 gallons) per minute discharge for

Use Teflon

 

 

 

shower waste

 

 

 

Tape Only

 

 

• OPTIONAL: sign-mounting hardware

 

645mm

 

Step 1: Secure base to floor

133mm

(25-3/8")

 

 

 

(5-1/4")

 

 

 

1. Install three suitable anchors (by installer)

 

 

 

 

for M10 bolts in the floor (see Figure 1).

 

 

610mm

 

2. Bolt the base to the floor anchors using M10

 

 

(24")

 

 

Ø 254mm

 

 

bolts (supplied by installer).

 

(10")

 

 

 

 

 

 

IMPORTANT: Some teflon sealants

 

 

1676mm

 

 

 

(66")

 

may cause stress cracks in the plastic

2160mm

 

To

 

 

Floor

 

showerhead leading to failure. Use

(7'-1")

 

 

 

 

 

To

 

 

 

teflon tape for sealing the showerhead.

Floor

229mm

140mm

 

 

 

 

(9")

Step 2: Assemble eyewash components

 

(5-1/2")

 

 

 

 

 

 

1. Assemble the remaining unit components as

 

 

 

 

shown in Figure 2 on page 4.

 

 

 

 

Apply pipe sealant (supplied by installer) to

 

 

 

 

 

all male-threaded pipe joints.

 

 

1041mm

 

 

 

 

(41")

 

Use the rubber grip pad provided or a strap

 

 

 

 

 

wrench around pipes when tightening to

 

 

 

 

 

prevent marring. Place the grip pad on the

 

 

152mm

 

 

pipe, then put the wrench over the grip pad

 

 

(6")

 

 

and turn the pipe with the wrench.

 

 

 

 

Bottom edge of showerhead should be

 

 

 

 

 

2160mm (7'-1") from floor.

NOTE: All dimensions assume standard thread

 

 

 

Step 3: Connect water supply

 

engagement. Variations in manufacturing allow

 

for +/- 1/8" (3mm) per threaded joint. To find

 

IMPORTANT: Do not rely on Bradley’s

 

the tolerance of a dimension, add the number

 

 

of thread joints in between a dimension and

 

Combination Unit to support supply

 

multiply it by 1/8" (3mm).

 

 

 

 

 

piping.

 

 

 

1. Connect water supply piping to 1-1/4" BSP inlet on unit (piping supplied by installer). Provide adequate supports (supplied by

installer) for supply pipe using pipe hangers or other means.

2.Connect drain piping to 1-1/4" BSP drain outlet on unit (piping supplied by installer).

3.Hang the safety sign from the unit with the curtain hooks provided (or mount it to the wall using sign-mounting hardware supplied by installer).

Bradley Corporation • 215-163DCE Rev. Z; EN 06-532F

6/25/07

3

Page 3
Image 3
Bradley Smoker E19-310DC Installation, Supplies Required, Secure base to floor, Assemble eyewash components, piping