Installation |
Installation |
| Ø 273mm |
| ||
Supplies Required: |
|
| |||
|
| 247mm | |||
• (3) M10 floor anchors and bolts |
|
| |||
|
|
| |||
• | Teflon tape and pipe sealant |
|
| Ø 229mm (9") Flange | |
• Piping to |
|
| with (3) Ø 10mm (3/8") | ||
|
| Holes on Ø 203mm (8") | |||
• | Adequate supply pipe supports |
|
| Bolt Circle | |
|
|
| |||
• Piping to |
| 267mm |
| ||
• | Minimum 102mm (4") drain to accommodate |
|
| ||
|
| ||||
| 115 liters (30 gallons) per minute discharge for | Use Teflon |
|
| |
| shower waste |
|
| ||
| Tape Only |
|
| ||
• OPTIONAL: |
| 645mm |
| ||
Step 1: Secure base to floor | 133mm |
| |||
|
| ||||
|
| ||||
| 1. Install three suitable anchors (by installer) |
|
|
| |
| for M10 bolts in the floor (see Figure 1). |
|
| 610mm | |
| 2. Bolt the base to the floor anchors using M10 |
|
| (24") | |
|
| Ø 254mm |
| ||
| bolts (supplied by installer). |
| (10") |
| |
|
|
|
| ||
| IMPORTANT: Some teflon sealants |
|
| 1676mm | |
|
|
| (66") | ||
| may cause stress cracks in the plastic | 2160mm |
| To | |
|
| Floor | |||
| showerhead leading to failure. Use |
| |||
|
|
| |||
| To |
|
| ||
| teflon tape for sealing the showerhead. | Floor | 229mm | 140mm | |
|
|
|
| (9") | |
Step 2: Assemble eyewash components |
| ||||
|
| ||||
|
|
| |||
| 1. Assemble the remaining unit components as |
|
|
| |
| shown in Figure 2 on page 4. |
|
|
| |
| • | Apply pipe sealant (supplied by installer) to |
|
|
|
|
| all |
|
| 1041mm |
|
|
|
| (41") | |
| • | Use the rubber grip pad provided or a strap |
|
|
|
|
| wrench around pipes when tightening to |
|
|
|
|
| prevent marring. Place the grip pad on the |
|
| 152mm |
|
| pipe, then put the wrench over the grip pad |
|
| (6") |
|
| and turn the pipe with the wrench. |
|
|
|
| • | Bottom edge of showerhead should be |
|
|
|
|
| 2160mm | NOTE: All dimensions assume standard thread | ||
|
|
| |||
Step 3: Connect water supply |
| engagement. Variations in manufacturing allow | |||
| for +/- 1/8" (3mm) per threaded joint. To find | ||||
| IMPORTANT: Do not rely on Bradley’s |
| the tolerance of a dimension, add the number | ||
|
| of thread joints in between a dimension and | |||
| Combination Unit to support supply |
| multiply it by 1/8" (3mm). | ||
|
|
|
| ||
| piping. |
|
|
|
1. Connect water supply piping to
installer) for supply pipe using pipe hangers or other means.
2.Connect drain piping to
3.Hang the safety sign from the unit with the curtain hooks provided (or mount it to the wall using
Bradley Corporation • | 6/25/07 | 3 |