Installation Instructions | |
|
|
Installation Instructions for Type H
Step 1: Install column shower components
NOTE: Flush supply lines before making connections.
1.Remove the five bolts that secure the disposable washer to the drain and lift the washer off.
2.Loosen the screw(s) securing the shower’s cover and lift the cover off. DO NOT remove the screw(s)!
3.Insert a 2" NPT vent pipe (supplied by installer) into the shower.
NOTE: Make sure that the vent pipe does not snag internal wiring or come in contact with the electronic components.
4.Position the shower over the drain and screw the 2" NPT vent pipe into the vent connection (see Figure 6).
5.Bolt the shower to the drain with the five bolts (removed in procedure #1) and oval washers provided (see Figure 5).
Step 2: Connect water supply
1.Remove the two
Figure 5
(5)
(5) WASHERS
2.Through access opening, connect water supplies to the shower’s 3/4" copper tubing as shown in Figure 6 (piping supplied by installer).
3.Slide column cover over vent.
NOTE: If you are installing a column shroud, slide the slip ring up the vent and supply piping first, and then slide column cover up (see page 7 for shroud installation).
4.Turn on water to the shower and test for leaks and adequate water flow.
5.Replace access panel onto shower with the
NOTE: For column shower drains with a dome grate, install the two halves of grate with the screws provided after the column installation is complete.
| Supplies from Below/Vent Through Column |
|
|
|
| Figure 6 |
| ||
|
|
|
|
|
|
|
|
|
|
Bradley Corporation • | 5 |