Metering Air Valve Maintenance

Terreon® Multi-Fount Washfountains

Parts and Service Guide

 

 

 

Metering Air Valve Maintenance

Adjust Air Valve Meter Time

NOTE: The air valve timer is located next to the tube connector on the air valve body. The timer is capped with a filter to prevent dirt build-up on the timer. The air valve timing can be adjusting from 5–60 seconds.

1.Remove filter cap and use a screwdriver to tighten or loosen the timer (see illustration at right). Turning the timer clockwise increases the time; turning the timer coun- terclockwise decreases the time.

2.Continue to adjust until the timer is set at desired length.

3.Replace filter cap over the timer.

Tube Connection Leaks

1.Push in the orange manual release button while pulling the tube out (see illustration at right) to disconnect the tube at the connector. No tools are needed.

2.To correct a leak, press tubing firmly into the connector and make sure it is seated.

3.If leak persists, remove tubing from the fitting, and trim the tubing end square with a razor-sharp knife. If leak con- tinues, replace the fitting or contact your Bradley represen- tative for assistance.

WATER TUBE CONNECTOR

AIR VALVE Adjust Air Valve Meter Time

FILTER CAP Tube Connection Leaks

AIR TUBE

CONNECTOR