Problem

Possible Cause

Solution

 

 

 

No water flow

Supply valves are closed

Open supply valves

 

 

 

 

Aerator is blocked or dirty

Clean or replace aerator (See "Care and Maintenance")

 

 

 

 

Inlet water line filter is dirty or

Clean or replace fi lter (See "Care and Maintenance")

 

blocked

 

 

 

 

 

Braided hose is kinked

Eliminate braided hose kink

 

 

 

 

No external water pressure

Check water pressure/Provide water pressure

 

 

 

 

Battery is drained (DC

Replace battery (See "Care and Maintenance")

 

faucets only)

 

 

 

 

 

Battery contacts are

Clean contacts or replace battery

 

corroded (DC faucets only)

(See "Care and Maintenance")

 

 

 

 

Reverse battery insertion

Insert battery correctly

 

 

 

 

Connector between

Plug connector

 

transformer and power

 

 

adapter unplugged (AC

 

 

faucets only)

 

 

 

 

 

Power adapter contacts are

Clean contacts

 

corroded (AC faucets only)

 

 

 

 

 

Connecting cable is kinked

Replace defective parts (See "Replacement Parts")

 

or broken (AC faucets only)

 

 

 

 

 

No external power supply

Check external power supply/Provide power supply

 

(AC faucets only)

 

 

 

 

 

Shut-off screw is missing or

Replace shut-off screw (See "Replacement Parts")

 

defective

 

 

 

 

 

Solenoid valve inoperable

Replace solenoid valve (See "Replacement Parts")

 

 

 

 

Faucet is in cleaning mode

Wait for cleaning mode to end (appr. 90 seconds)

 

 

 

 

Electronics module

Contact Bradley technical service or replace power adapter (See

 

inoperable

“Replacement Parts”)

 

 

 

 

Power adapter defective (AC

Contact Bradley technical service or replace power adapter (See

 

faucets only)

“Replacement Parts”)

 

 

 

 

Sensor distance is not

Reset sensor monitoring range

 

adjusted properly

Remove and re-install shut-off screw. Do not disturb sensor scanning

 

 

procedure (wait until water fl ow stops and LED switches off)

 

 

 

 

Infrared window sctatched

Clean window with smooth cloth

 

or dirty

 

 

 

 