,#$#%RROR #ODES

Listed below are codes that the lift controller outputs during lift operation. The codes will be displayed on an LCD screen located on the lift control board inside the pump module. See the Manual Operating Instructions in the operator's manual for pump cover removal instructions.

Non-Flashing Numbers

01 – Platform stowed

02 – Platform unfolding

03 – Platform unfolding paused

04 – Platform at floor level

05 – Platform beginning to lower

06 – Platform lowering (threshold cannot be occupied from this point down)

07 – Outer barrier moving to horizontal position

08 – Platform at ground level

09 – Outer barrier moving to vertical position

10 – Platform raising

11 – Platform raising paused at floor

12 – Platform folding (limited pressure)

13 – Platform folding (full pressure)

14 – Timed fold (cinching lift tite) or (anti-rattle state) 15 – Platform folding stopped

16 – Paused fold

17 – Platform between ground and 3” above ground

18 – Platform above 3”

28– Illegal function/not defined

29– Interlock fault not recognized (or has been cleared but a motion button is still pressed)

30– Platform location unknown

31– Platform location transition state; attempting to locate position

50 – Outboard barrier is not up above inboard barrier locked position

51 – Threshold is occupied when platform is 1” or more below floor level

52 – Inboard barrier is not up and locked below inboard barrier locked position

53 – Inboard barrier occupied sensor is not activated between floor and inboard barrier up position

54 – Outboard barrier is occupied before it is up

55 – Outboard barrier is not latched when above the inboard barrier locked position (Millennium only)

56 – Outboard barrier is not up and latched and bridge switch did not deactivate

57 – Outboard barrier is not up and latched and ground detect switch did not deactivate (Century and Vista only)

58 – Outboard barrier is not up and latched and the plat- form is 3” above the ground

59 – Outboard barrier is not up after pausing platform travel

75 – Low voltage detected; must turn off power switch to reset LCD

77 – Vehicle secure interlock has not been activated

90 – Position will be set if you keep holding the button until it beeps

91 – Position is out of a predetermined acceptable range of floor position

92 – Bridge switch is not made, needs adjusting

93 – Inboard barrier occupied switch is not made, posi- tion needs to be moved or switch should be ad- justed

94 – Outboard barrier is not made, fix and try again

95 – Outboard barrier latch is not made (check for jumper on Century and Vista lifts, check latch on Millennium lifts)

99 – Controller program is not valid; replace controller

Flashing Numbers

Flashing 65 – Unfold button is pressed Flashing 66 – Fold button is pressed Flashing 67 – Down button is pressed Flashing 68 – Up button is pressed Flashing 69 – Bridge switch is activated

Flashing 70 – Outboard barrier latch switch is activated Flashing 71 – Ground detect switch is activated Flashing 72 – Outboard barrier up switch is activated Flashing 73 – Inboard barrier up switch is activated Flashing 74 – Inboard barrier occupied switch is acti-

vated

Flashing 76 – Outboard barrier occupied switch is activated

Flashing 78 – Threshold tape switch “A” is activated Flashing 79 – Threshold tape switch “B” is activated Flashing 80 – Position set button is pressed

Page 7

Page 9
Image 9
Braun A2 service manual #$#%Rror #Odes, Non-Flashing Numbers