small amount of oil, the cleaning procedure also fulfills the lubrication needs of the shaver.
Important
•Only use the power supply cord set supplied with the shaver.
•In order to avoid any leakage of the cleaning fluid, place the appliance on a flat, stable surface. Do not tip, move suddenly or transport in any way if a cleaning cartridge is installed.
•Do not place the appliance in a mirror cabi- net, nor store it over radiators, nor place it on polished or laquered surfaces. Do not expose to direct sunlight.
•The appliance contains highly flammable liquid. Keep it away from sources of ignition. No smoking.
Keep out of reach of children. Do not refill cartridge. Use only original Braun refill cartridge.
•When cleaning the shaver, its protection cap should be removed.
Description
1Lift button for cartridge exchange
2Contact bow
3Start/release button
4Level indicator
5Cleaning cartridge
Before using Clean&Renew™
Installing the cartridge
•Press the lift button (1) to open the housing.
•Hold the cartridge down on a flat, stable surface (e.g. table). Carefully remove the lid from the cartridge. Slide the cartridge into the base as far as it will go.
Slowly close the housing by pushing it down until it locks.
Replacing the cartridge
After having pressed the lift button to open the housing, wait for a few seconds before re- moving the used cartridge.
Before discarding the used cartridge, make sure to close the openings using the lid of the new cartridge, since the used cartridge will contain contaminated cleaning solution.
The used cartridge can be disposed in the household waste.
Operating your
Clean&Renew™
•Connect your Clean&Renew™ with the cord set to the mains electricity supply. The special socket at the back is adjustable to save space. After each shave, switch the shaver off and put it into the Clean&Renew™, upside down and with the front showing.
•Push the start/release button (3) to lock and connect the shaver. The cleaning process will start. The yellow light on the shaver will flash during the complete process (approx. 5 minutes cleaning, 4 hours drying).
•Do not interrupt the cleaning process, as it leaves the shaver wet and not fit for use. If interruption is needed nonetheless, press the start/release button (3).
•When cleaning is finished, the yellow light will go off and the shaver is ready for use. To release it, push the start/release button.
•A cleaning cartridge should be sufficient for about 30 cleaning cycles. When the level indicator (4) has reached the «min» mark, the remaining fluid in the cartridge is suf- ficient for about 5 more cleaning cycles. Then the cartridge should be replaced, when used daily approx. every 4 weeks.
•The hygienic cleaning solution cartridge contains alcohol which, once opened, will naturally evaporate slowly into the surrounding air. Each cartridge, if not used daily should be replaced after approx.
8 weeks.
•Clean the housing from time to time with a damp cloth, especially the opening where the shaver rests.
Subject to change without notice.
8