LIGHTING THE ROTISSERIE BURNER:

1.Open grill hood before lighting rotisserie burner.

2.Make sure control knob is in the "OFF" position.

3. Push and turn the control knob of that burner to the "HIGH" position. Continue to push in control knob while pressing electronic igniter for 3 – 5 seconds.

4.Once burner is lit, continue to push and hold control knob for 30 seconds.

5.If ignition does NOT occur in 5 seconds, turn control knob to

"OFF”, wait 5 minutes to allow gas to dissipate and repeat lighting procedure.

6. To turn off, turn each control knob clockwise until it locks in the "OFF" position.

IMPORTANT: DO NOT use back rotisserie burner when main burners are in use.

Note: If burner does not light or flame is too low, you may have spider or other insect blockage in burner, or the flow limiting device has been activated. See "Burner Assembly/Maintenance" under Proper Care and Maintenance, or "Regulator Resetting Procedure" under Connecting LP Cylinder and Hose/Regulator to Grill.

MATCH LIGHTING THE ROTISSERIE BURNER:

1.Open grill hood before lighting rotisserie burner.

2.Make sure control knob is in the "OFF" position.

3.Strike and carefully place a match approximately 1/2" (1 to 2 cm) from the lower edge of burner.

4.Push and turn the control knob of that burner to the "HIGH" position. The burner should light within 5 seconds.

5.Once burner is lit, continue to push and hold control knob for 30 seconds.

6.If the burner does not light, turn the control knob to "OFF" and wait 5 minutes for gas to dissipate and repeat lighting procedure.

7.If the burner does not light within the first few attempts of match lighting, there is a problem with the gas supply. Turn off the gas at the burner and cylinder. DO NOT attempt to operate the grill until the problem is found and corrected. See "Trouble Shooting" section of this manual.

LIGHTING THE SIDE BURNER:

1.Open lid before lighting side burner.

2.Make sure control knob is in the "OFF" position.

3. Push and turn side burner control knob to the "HIGH" position.

4.Press the electronic igniter on the main control panel and hold for 3 – 5 seconds to light burner.

5. If ignition does NOT occur in 5 seconds, turn control knob to "OFF", wait 5 minutes to allow gas to dissipate and repeat lighting procedure.

6. To turn off, turn each control knob clockwise until it locks in the "OFF" position.

Note: If burner does not light or flame is too low, you may have spider or other insect blockage in burner, or the flow limiting device has been activated. See "Burner Assembly/Maintenance" under Proper Care and Maintenance, or "Regulator Resetting Procedure" under Connecting LP Cylinder and Hose/Regulator to Grill.

11

Page 12
Image 12
Brinkmann Series 4435 owner manual Match Lighting the Rotisserie Burner, Lighting the Side Burner

Series 4435 specifications

The Brinkmann Series 4435 is a notable addition to the realm of analytical laboratory instruments, designed primarily for high-performance liquid chromatography (HPLC). Known for its precision, reliability, and user-friendly operation, this series provides essential support in various applications, including drug development, environmental monitoring, and food safety testing.

One of the main features of the Brinkmann Series 4435 is its innovative pump design, which ensures consistent flow rates and pressure stability. This is critical for achieving accurate and reproducible results in chromatographic analyses. The pump's hermetically sealed construction minimizes the risk of sample contamination, making it a preferred choice for sensitive analytical tasks.

Equipped with advanced technology, the Brinkmann Series 4435 utilizes a dual-channel detection system that enhances sensitivity and selectivity. This system allows simultaneous monitoring of multiple analytes, significantly improving throughput in a busy laboratory setting. The integration of state-of-the-art photodiode array (PDA) detectors facilitates the collection of spectral data across a wide wavelength range, providing researchers with comprehensive insights into sample composition.

The instrument's user interface is designed to be intuitive, allowing operators to set up methods and control the instrument effortlessly. The touch screen display provides real-time data visualization, which helps in monitoring the separation process as it occurs. The flexibility of the Brinkmann Series 4435 also extends to its compatibility with various chromatographic columns, enabling users to adapt the system to different applications as needed.

Durability and maintenance ease are additional characteristics that distinguish the Brinkmann Series 4435 from other models. The robust construction ensures long-term operation without frequent breakdowns, while its modular design allows for simple repairs and component replacements.

In summary, the Brinkmann Series 4435 stands out for its high-performance capabilities and advanced technologies, including a reliable pump system, dual-channel detection, and an intuitive user interface. These features make it an ideal instrument for laboratories striving for accuracy, efficiency, and versatility in their analytical processes. Whether for routine analysis or complex research applications, the Brinkmann Series 4435 delivers exceptional performance that meets the demands of modern analytical chemistry.