UNDERSTANDING YOUR CO ALARM

BASIC POWER CONDITIONS

Alarm operating

 

“Err” Alarm is

on AC power

 

not operating

 

 

properly

 

 

 

What you see and hear during installation

INSTALLATION

WHERE TO INSTALL CO ALARMS

The National Fire Protection Association (NFPA) recommends that a CO Alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms. For added protection, install additional CO Alarms in each separate bedroom, and on every level of your home.

If your bedroom hallway is longer than 40 feet (12 meters), install a CO Alarm at BOTH ends of the hallway.

WHEN YOU FIRST PLUG-IN THE CO ALARM:

HORN: May chirp briefly

DISPLAY: Dash appears by “READY”

POWER/ALARM LIGHT:

Shines continuously

UNDER NORMAL CONDITIONS (AC POWER):

HORN: Silent

DISPLAY: Dash remains lit at “READY”

POWER/ALARM LIGHT: Shines continuously

WHEN YOU TEST THE CO ALARM:

HORN: Sounds loudly - 4 beeps, pause, 4 beeps, pause

DISPLAY: Flashes “888” briefly

POWER/ALARM LIGHT:

Flashes rapidly

BEDROOM

BEDROOM

BEDROOM

 

KITCHEN

GARAGE

LIVING ROOM

HALL

 

 

BASEMENT

 

What you see and hear under different conditions:

WHEN THE ELECTRICITY COMES

IF THE CO ALARM IS NOT

BACK ON:

OPERATING PROPERLY:

HORN: May chirp briefly

HORN: Three rapid chirps

DISPLAY: Dash appears by

every minute

DISPLAY: Displays “Err”

“READY”

POWER/ALARM LIGHT: Shines

POWER/ALARM LIGHT: Flashes

continuously.

three times in sync with the horn.

What you see and hear if CO is detected:

REQUIRED TO MEET NFPA RECOMMENDATIONS SUGGESTED AREAS FOR INSTALLING ADDITIONAL CO ALARMS

In a Single-level Home:

Install at least one CO Alarm near or within each separate sleeping area.

For added protection, install an additional CO Alarm at least 20 feet (6 meters) away from the furnace or fuel burning heat source.

In a Multi-level Home:

• Install at least one CO Alarm near or within each separate sleeping area.

For added protection, install at least one CO Alarm on each level of the

 

home. If you have a basement, install that CO Alarm at the top of the

 

basement stairs.

For added protection, install an additional CO Alarm at least 20 feet

PRE-ALARM LEVELS:

HORN: Silent

DISPLAY: Shows CO levels detected in ppm

POWER/ALARM LIGHT:

On continuously

ALARM LEVELS OF CO ARE DETECTED:

HORN: Sounds loudly - 4 beeps, pause, 4 beeps, pause.

This sequence repeats for as long as the unit is in alarm*

DISPLAY: Shows CO levels detected in ppm

POWER/ALARM LIGHT:

Flashes rapidly

IF YOU SILENCE THE ALARM:

HORN: Silent for about 4 minutes*

DISPLAY: Shows CO levels detected in ppm

POWER/ALARM LIGHT:

Flashes rapidly

*Note: After 4 minutes, if CO lev- els drop below alarm levels, the unit will remain silent and return to normal operation. If CO pres- ence still indicates a potentially dangerous situation, the horn will sound again.

IF THE CO LEVELS RETURN TO NORMAL:

HORN: Silent

DISPLAY: Dash lit by “READY”

POWER/ALARM LIGHT:

Shines continuously

(6 meters) away from the furnace or fuel burning heat source.

This unit should receive continuous electrical power. Choose an outlet where it can’t be accidentally unplugged or switched off by children. Keep small children away from the unit. Teach them not to play with it or unplug it. Explain what the alarms mean.

WHERE CO ALARMS SHOULD NOT BE INSTALLED

DO NOT locate this CO Alarm:

• In garages, kitchens, furnace rooms, or in any extremely dusty, dirty

or greasy areas.

• Closer than 15 feet (4.6 meters) from a furnace or other fuel burning heat

source, or fuel burning appliances like a water heater.

• Within 5 feet (1.5 meters) of any cooking appliance.

• In extremely humid areas. This Alarm should be at least 10 feet (3 meters)

from a bath or shower, sauna, humidifier, vaporizer, dishwasher, laundry

room, utility room or other source of high humidity.

• In areas where temperature is colder than 40˚F (4˚C) or hotter than 100˚F

(38˚C). These areas include non-airconditioned crawl spaces, unfinished

attics, uninsulated or poorly insulated ceilings, porches, and garages.

• In turbulent air, like near ceiling fans, heat vents, air conditioners,

fresh air returns, or open windows. Blowing air may prevent CO from

reaching the sensors.

USING THE PEAK CO MEMORY

The CO Memory Feature lets you check the highest level of CO recorded during an alarm.

To check CO Memory:

1.Press and release the Test/Silence/Scroll button until the dash scrolls to “MEMORY”.

2.Press and hold Test/Silence/Scroll button to display Memory CO level.

To clear CO Memory:

1.Press and release the Test/Silence/Scroll button until the dash scrolls to “CLEAR MEMORY.”

2.Press and hold the Test/Silence/Scroll button until the display shows “CLr.”

NOTE: The highest CO level will be saved, even after a power interruption, until you clear it. DO NOT clear the CO Memory reading if you plan to call someone to investigate a CO problem! Clear the CO Memory reading only after the investigator has checked your home.

• In direct sunlight.

• In outlets covered by curtains or other obstruction.

• This CO Alarm is designed for use inside a single-family home or

apartment. It is not meant to be used in common lobbies, hallways, or

basements of multi-family buildings unless working CO Alarms are

also installed in each family living unit. CO Alarms in common areas

may not be heard from inside individual family living units.

• This CO Alarm alone is not a suitable substitute for complete

detection systems in places which house many people, like hotels or

dormitories, unless a CO Alarm is also placed in each unit.

• DO NOT use this CO Alarm in warehouses, industrial or commercial

buildings, special-purpose non-residential buildings, RVs, boats,

or airplanes. This CO Alarm is specifically designed for residential

use, and may not provide adequate protection in non-residential

applications.

2

Page 2
Image 2
BRK electronic FCD2DDNP user manual Installation, Understanding Your CO Alarm, Where CO Alarms should not be Installed

FCD2DDNP specifications

The BRK electronic FCD2DDNP is a state-of-the-art smoke and carbon monoxide alarm designed for residential and commercial safety. This device exemplifies the best in advanced detection technologies, ensuring users benefit from reliable protection against the dangers posed by smoke, fire, and harmful gases.

One of the key features of the FCD2DDNP is its dual-sensor technology. This innovative approach combines both photoelectric and ionization sensors, allowing the alarm to detect a wide range of fire types. Photoelectric sensors are particularly effective for detecting smoldering fires, which may produce a lot of smoke without much heat. On the other hand, ionization sensors are more responsive to fast-flaming fires, providing a comprehensive detection capability that enhances overall safety.

Another significant characteristic of the FCD2DDNP is its built-in carbon monoxide detector. Carbon monoxide is a silent killer, and this device actively monitors levels of this dangerous gas in the environment. The integrated CO sensor provides an additional layer of security, alerting users to dangerous conditions before they become life-threatening.

The FCD2DDNP also features a user-friendly design. Its intuitive controls allow for easy testing and maintenance, ensuring that the device is functioning correctly at all times. The alarm is equipped with a loud 85-decibel siren, which guarantees that alerts can be heard even during the night, crucial for waking individuals and ensuring their safety.

Moreover, the FCD2DDNP is designed with a long-lasting battery life. The device typically uses a sealed lithium battery that can last for up to 10 years, eliminating the need for frequent replacements. This feature not only enhances convenience but also ensures that the alarm remains operational without regular maintenance concerns.

In addition to its technical capabilities, the FCD2DDNP encompasses a sleek and unobtrusive design, making it easy to integrate into various home aesthetics. With its compact size, it can be installed in multiple locations, from hallways to living rooms, enhancing safety without compromising the visual appeal of the environment.

Lastly, the BRK electronic FCD2DDNP is compliant with rigorous safety standards, offering peace of mind for users. With its combination of advanced detection technologies, user-friendly features, and reliable performance, the FCD2DDNP stands out as a top choice for anyone looking to enhance their safety and protection against fire and carbon monoxide hazards.