BRK electronic CSA6.19 Brown Wire, Gray Wire, Blue Wire Normally Open Contact, Voltage Resistive

Models: CSA6.19 ULCS-531 ULCS-530 UL217

1 2
Download 2 pages 44.78 Kb
Page 2
Image 2

CAT.RM4

This accessory relay is designed to activate auxiliary devices such as bells, lights and door closers. The RM4 Relay is intended for use with BRK and First Alert Smoke, Heat, and Carbon Monoxide Alarms.

Alarm

 

 

 

 

 

 

 

Auxiliary Device

 

BRK

 

BRK

 

 

 

 

AC Power

AC

 

Relay

 

 

 

 

Alarm

 

Auxiliary

 

 

Power

 

Module

 

 

 

 

 

 

 

Device

 

 

 

 

 

 

 

 

 

 

 

A R C H I T E C T U R A L A N D E N G I N E E R I N G S P E C

To install this relay to an alarm, connect the power wires as listed below. See diagram for connections. Note: If wiring the relay remote from the alarm, use a maximum of 1000 feet [300 meters] of #18AWG or larger wire rated at least 300V.

ALARM

CONNECTION

RELAY

BLACK WIRE

(HOT)

BLACK WIRE

WHITE WIRE

(NEUTRAL)

WHITE WIRE

ORANGE WIRE

(INTERCONNECT)

ORANGE WIRE

Now connect the accessory to be activated by the relay to the relay’s switch contact wires as listed below. (Use wiring appropriate to the auxiliary device being controlled.) NOTE: Since voltage is present on all relay contact wires at some time during operation, the installer must properly insulate any unused relay contact wire.

BROWN WIRE:

HOT CONTACT TO AUXILIARY DEVICE

GRAY WIRE:

NORMALLY CLOSED CONTACT

BLUE WIRE:

NORMALLY OPEN CONTACT

 

 

 

BROWN

 

 

 

BLUE

(COM.)

GRAY

 

 

(N.O.)

 

(N.C.)

WHITE

ORANGE

BLACK

 

 

 

 

 

 

 

 

WHITE

ORANGE

BLACK

 

 

NEUTRAL

 

 

 

 

INTERCONNECT

 

 

 

 

HOT

 

 

{

 

 

 

{

UNSWITCHED 120V AC

TO ADDITIONAL ALARMS

60 Hz SOURCE

 

CONTACT RATINGS (MAXIMUM):

VOLTAGE

RESISTIVE

MOTOR

120V AC

15 AMP

1/3 H.P.

30V

DC 15 AMP

 

After installation, test the interaction of the auxiliary device with the alarm by pressing the alarm test button.

T E C H N I C A L S P E C S

Dimensions:

3.5 L x 1.5 H

Weight:

2.2 oz

 

 

Operating Voltage:

120V AC 60Hz

 

 

Operating Current:

.02 amps (standby/alarm)

 

 

Temperature Range:

40°F (4°C) to 100°F (38°C)

 

 

Humidity Range:

10% to 90% relative humidity (RH)

 

 

Interconnections:

Up to 18 units of First Alert or BRK Smoke, CO and

 

Heat Alarms. Maximum of 12 smoke alarms. See

 

user’s manual for details.

Listing:

Meets UL217, UL2034, UL539,ULC S-531,

 

CSA6.19 and ULCS-530 for accessories.

 

 

S H I P P I N G S P E C S :

Individual Bag Dim. (Approx.)

6.25"L x 1.50"W x 5.00"H

Weight

0.16 lbs.

Cube

0.03 ft3

UPC

0 29054 00057 6

 

 

Master Carton Dimensions

10.25"L x 4.75"W x 6.38"H

Master Pack

12

Weight

2.1 lbs.

Cube:

0.19 ft3

I2of5:

100 29054 00057 3

 

 

Pallet Information

 

Cases per Layer

35

Number of Layers:

6

Cases per Pallet:

210

Units per Pallet:

2,520

Cube:

54.7 ft3

Weight:

695 lbs.

©2009 BRK Brands, Inc. a Jarden Corporation

Company (NYSE: JAH)

3901 Liberty Street Road Aurora, IL 60504-8122 All rights reserved

 

First Alert is a registered trademark of the First Alert Trust

brkelectronics.com

BRK is a registered trademark of BRK Brands, Inc.

 

CM2946

Page 2
Image 2
BRK electronic CSA6.19, ULCS-531 Brown Wire, Gray Wire, Blue Wire Normally Open Contact, Voltage Resistive, DC 15 AMP, Upc

CSA6.19, ULCS-531, ULCS-530, UL217 specifications

BRK electronic is a renowned name in the field of fire safety technology, offering a broad spectrum of smoke and carbon monoxide detectors designed to enhance safety in residential and commercial settings. Among their notable product offerings are the ULCS-531, ULCS-530, UL217, and CSA6.19 models, each showcasing advanced features and cutting-edge technologies designed to provide reliable alerts and enhance overall safety.

The ULCS-531 model is a photoelectric smoke alarm that utilizes advanced sensing technologies to detect smoke more effectively. With its robust design, it incorporates a high-performance photoelectric sensor that responds quickly to smoldering fires, reducing false alarms often triggered by common household activities. Its sleek and modern appearance allows it to seamlessly integrate into a variety of home décors, ensuring that safety is not compromised for aesthetics.

The ULCS-530 is renowned for its dual-sensor technology, combining both photoelectric and ionization sensing methods to provide comprehensive coverage against various types of fires. This dual approach ensures fast detection of both flaming and smoldering fires. Additionally, it comes equipped with a loud alarm and features a safety light for easy location in low-visibility conditions. The ULCS-530 also boasts a user-friendly interface, allowing for simple maintenance and testing.

The UL217 model focuses on smart technology integration and connectivity, featuring Wi-Fi capabilities that enable users to monitor and receive alerts directly on their smartphones or tablets. This real-time notification feature allows homeowners to be aware of potential fire hazards even when they are not at home. The UL217 also includes a built-in voice alert system that announces the type of hazard detected, aiding in swift emergency responses.

Lastly, the CSA6.19 model emphasizes energy efficiency along with its detection capabilities. This model is designed to be eco-friendly, promoting sustainability while maintaining the highest safety standards. With low-power consumption technology, it not only contributes to reducing electricity bills but also extends the life of its battery.

In conclusion, the BRK electronic models ULCS-531, ULCS-530, UL217, and CSA6.19 stand out for their innovation and reliability. With advanced technologies like dual-sensor systems, smart connectivity, and eco-friendly designs, these detectors ensure safety and peace of mind for families and businesses alike. The emphasis on user experience and effective fire detection makes BRK electronic a leader in the industry, continually pushing the boundaries of fire safety technology.