MODEL 336
EXTERIOR MOUNTED BLOWER
FOR USE WITH RANGEMASTER 60000 OR RM60000 SERIES OR 64000 SERIES RANGE HOODS FOR USE WITH "BEST BY BROAN"
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.Use this unit only in the manner intended by the manufac- turer. If you have questions, contact the manufacturer at the address or phone number listed in the warranty.
2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including
4.Sufficient air is needed for proper combustion and exhaust- ing of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equip- ment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
WARNING
5.When cutting or drilling into wall, or ceiling, do not damage electrical wiring or other hidden utilities.
6.Ducted fans must always be vented to the outdoors.
7.To reduce risk of fire, use only metal ductwork.
8.This unit must be grounded.
CAUTION
1.For general ventilating use only. Do not use to exhaust hazardous or explosive material and vapors.
2.To avoid motor bearing damage and noisy and/or unbal- anced impellers, keep drywall spray, construction dust, etc. off power unit.
3.Please read specification label on product for further informa- tion and requirements.
4.Electrical circuit, including speed control, (if used), must be rated 6 AMPS minimum.
SPECIFICATIONS
MODEL | VOLTS | AMPS | CFM | DUCT SIZE |
336 | 120 | 3.8 | 1500 | 10" DIA. |
|
|
|
|
|
PLAN THE INSTALLATION
ALL INSTALLATIONS
1.Locate the blower so the length of the duct run and number of elbows needed are kept to a minimum.
2.Where possible, blower should be centered between wall studs or roof rafters.
3.Avoid pipes, wires, or other ductwork that may be running through the wall.
NOTE: Horizontal discharge requires relocation of the duct opening cover plate. See hood manual for instructions.
MODEL 336 |
|
|
|
|
|
|
|
EXTERIOR BLOWER |
|
|
|
|
|
| |
|
| 10" ROUND ELBOW |
|
|
|
| |
| 10" ROUND |
| 10" ROUND DUCT |
|
| 10" ROUND DUCT | |
| DUCT |
|
|
|
|
|
|
SOFFIT |
| SOFFIT |
|
| SOFFIT |
| DUCT |
|
|
| MODEL |
|
| ||
WALL HOOD | WALL HOOD |
| WALL HOOD |
| OPENING | ||
PLATE |
| 336 |
| ||||
CANOPY | CANOPY |
| CANOPY |
| COVER | ||
|
| EXTERIOR |
| ||||
(island canopy |
| (island canopy |
| (island canopy |
| PLATE | |
|
| BLOWER |
| ||||
available) |
| available) |
| available) |
|
| |
|
|
|
| MODEL | |||
DUCT |
| DUCT |
|
|
| ||
|
|
|
| 336 | |||
OPENING | 18" | OPENING | 18" |
| 18" | ||
PLATE |
| EXTERIOR | |||||
COVER PLATE |
| COVER PLATE |
|
|
| ||
|
|
|
|
|
|
| BLOWER |
24" or 27" |
| 24" or 27" |
|
| 24" or 27" | ||
|
|
| PLATE | ||||
|
|
|
|
|
|
| |
TYPICAL ROOF MOUNTED INSTALLATION | TYPICAL WALL MOUNTED INSTALLATION | TYPICAL WALL MOUNTED INSTALLATION | |||||
(Verticaldischarge) | (Vertical discharge - elbow to horizontal) |
| (Horizontaldischarge) |
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4