12 Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B • 4036-909 Rev D • 08/06
E. Valve AccessWasher
Figure 6.1 Lift Out Doors
Figure 6.3 Loosen Refractory Retaining Strip
Figure 6.4 Remove Valve Access Panel
Figure 6.5 Remove Exterior Valve Access Panel
Figure 6.6 Connect Manometer
• The gas valve can be accessed behind the cement
refractory panel on the right side of the fi replace.
• Lift doors out and set aside. There is a washer under each
door. Be careful not to loose those washers.
• Use a phillips screwdriver to remove the exterior valve
access panel (remove four screws).
• Use a manometer on the lower out pressure tap. Start
up the fi replace to verify the pressure and adjust as
necessary. Reverse these steps to reassemble before log
positioning.
• Remove logs if access is necessary after installation is
complete. See Section 9.C. Remove logs in reverse order
of set up.
• Remove grate if access is necessary after installation is
complete. (Refer to Section 9.B.)
• Remove two screws on side of pilot shield and remove
shield.
• Remove the inside valve access panel by lifting it up and
out.
Figure 6.2 Remove Pilot Shield
• Use a phillips screwdriver to remove the two screws
securing the refractory retaining strip. Remove the
refractory side panel and set aside.