Broan C305, C306 manual Installation, Do Not Oil Chime Plungers, Read And Save These Instructions

Models: C306 C305 C305RW

1 4
Download 4 pages 15.82 Kb
Page 1
Image 1
MODEL C305

MODEL C305

MODEL C305RW

MODEL C306

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION

ALL ELECTRICAL WORK MUST BE DONE IN ACCORDANCE WITH LOCAL AND/ OR NATIONAL ELECTRICAL CODE AS APPLICABLE.

TURN OFF POWER AT SERVICE ENTRANCE BEFORE INSTALLING, WIRING, OR SERVICING THIS PRODUCT.

1.Hold chime mechanism against wall and mark four (4) mounting holes.

2.Drill 3/16” holes where marked and tap in wall anchors from parts bag.

3.Bring wiring through access hole(s) in chime mechanism backplate.

4.Loosely attach chime mechanism to wall with screws from parts bag.

5.C306 only. Slide brackets under screw heads.

6.Tighten screws securely.

C306 only

C306 only

DO NOT OIL CHIME PLUNGERS.

Oil will cause them to stick during operation. If plungers fail to operate freely due to accumulation of dust, cooking grease, etc., clean with a non-flammable cleaning solvent which will evaporate, leaving a dry surface.