READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELEC- TRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have ques- tions, contact the manufacturer at the address or telephone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on acciden- tally. When the service disconnecting means cannot be locked, securely fas- ten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construc- tion codes and standards.

4.Sufficient air is needed for proper com- bustion and exhausting of gases through the flue (chimney) of fuel burning equip- ment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,

SPECIFICATIONS

WARNING

Refrigeration and Air Conditioning Engi- neers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall, or ceil- ing, do not damage electrical wiring or other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.To reduce risk of fire, use only metal ductwork.

8.This unit must be grounded.

CAUTION

1.For general ventilating use only. Do not use to exhaust hazardous or explosive material and vapors.

2.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

3.Please read specification label on prod- uct for further information and require- ments.

4.Electrical circuit, including speed control, (if used), must be rated 6 AMPS mini- mum.

INSTALLER: Leave This Manual With

The Homeowner.

HOMEOWNER: Use And Care

Information On Page 6.

MODEL

VOLTS

AMPS

CFM

DUCT SIZE

EB15

120

3.8

1500

10 " DIA.

 

 

 

 

 

PLAN THE INSTALLATION

ALL INSTALLATIONS

1.Locate the blower so the length of the duct run and number of elbows are kept to a minimum.

10" ROUND ELBOW

10" ROUND DUCT

SOFFIT

MODEL

2.Where possible, blower should be centered be- tween wall studs or roof rafters.

3.Avoid pipes, wires, or other ductwork that may be running through the wall.

4.Attach mounting plate to top of hood.

5.Install 10” dia. ductwork and 120 VAC house wir- ing between blower lo- cation and hood location.

MODEL EB15

 

EXTERIOR BLOWER

 

 

10" ROUND

 

DUCT

SOFFIT

 

 

ROUGH-IN

ALL HOOD

PLATE

 

CANOPY

 

10"

 

or

 

18"

 

21" or 24"

2

WALL HOOD

EB15

EXTERIOR

CANOPY

BLOWER

10"

 

or

 

18"

 

 

ROUGH-IN

21" or 24"

PLATE

TYPICAL WALL
MOUNTED
INSTALLATION
TYPICAL

 

ROOF MOUNTED

 

INSTALLATION

 

Page 2
Image 2
Broan EB15 Read And Save These Instructions, Specifications, Plan The Installation, All Installations, Information On Page