Broan E4DLSRCB, P408ICAT, MH4CFL42E installation instructions Internal Blower Hood Only

Models: E4DLSR E4DLSRCB MH4CFL42E P408ICAT

1 16
Download 16 pages 54.98 Kb
Page 10
Image 10
(INTERNAL BLOWER HOOD ONLY)

7. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) ONLY)

Slide the blower to disengage its flange from the retaining bracket.

HD0270

Flip the blower and engage its flange in the back wall retaining bracket.

Using a 5/16” socket and the screws previously removed, secure the blower to the hood.

HD0271

LEFT SIDE

MOUNTING

SCREW

LOCATION

RIGHT SIDE

MOUNTING

SCREW

LOCATION

HD0272

Plug the blower in.

NOTE FOR DUAL BLOWER HOOD ONLY: Cut off the plastic tie wrap on left motor cable.

HE0085

8. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)

(INTERNAL BLOWER HOOD ONLY)

Using standard 3/8’’ screws provided, secure the adapter to the top (or back) of the hood (2 screws for a 3¼” x 10” adapter/damper and 4 screws for a 4½” x 18½” adapter). Seal the adapter to the hood using duct tape. For round ducting, install an appropriate sized transition and seal the joints with duct tape.

HJ0013

9. INSTALL ANKE60 RECIRCULATION KIT (NON DUCTED INSTALLATION ONLY)

Refer to the installation sheet included with the recirculation kit for details.

- 10 -