HEAT SENTRY SYSTEM

MODELS QP430SS • QP436SS • QP442SS

HEAT SENTRY SYSTEM

This range hood is equipped with an advanced Heat Sentry system that monitors excessive temperature and automatically adjusts the fan to the appropriate setting.

1)If the fan is on, the Heat Sentry system will increase the fan setting when the temperature is elevated. If the temperature continues to rise, the Heat Sentry system will continue to increase the fan setting until the temperature is stabilized or reduced. The flashing light above the fan button shows the Heat Sentry system fan setting. Once the temperature has reduced, the Heat Sentry system will change the fan to the original setting.

2)If the fan is off, the Heat Sentry system will automatically turn the fan on to its highest speed when the temperature is above normal. When the Heat Sentry system is on, the light above the high speed fan button will flash on and off. After the temperature has lowered to normal, the fan speed will be reduced until the temperature has stabilized, then the fan will turn off.

Page 4

MAKE-UP AIR DAMPER

The hood is compatible with Broan Make-Up Air Damper Model MD6T or Model MD8T (optional). Purchase separately.

Make the connection to the Make-Up Air Damper with low voltage wiring, as shown. See Make-Up Air Damper instructions for additional information.

BACK OF HOOD

LOW-VOLTAGE CONNECTOR

 

FOR MAKE-UP AIR DAMPER

 

RANGE

MAKE-UP AIR

HOOD

DAMPER

Note: Canadian version does not have this function.

FUSES

 

 

RANGE HOOD CONTROL BOARD

MAIN

LIGHT

FUSE

FUSE

LOW-VOLTAGE

WIRES

120

VAC

MAKE-UP AIR DAMPER 24 FUSES

REMOTE CONTROL VAC

DAMPER

MOTOR

The Range Hood Control Board contains a Main Fuse and a Light Fuse to protect the controls from power surges. If a fuse has opened (blown), the green fan setting or light setting indicators will not operate properly when the fan or light buttons are pressed, and the fan and lights will not turn on.

New fuses can be purchased at your local electronic supply store. Use 8A, 120V, 5 mm diameter, 20 mm long, fast-acting, cartridge- type fuses.

To replace a fuse (by qualified person(s):

1.Disconnect power at service entrance.

2.Remove filters and bottom pan.

3.Remove and inspect fuse. If it is not open (blown), additional diagnostics are needed.