Broan RME50000 manual Operation, Light Bulbs, Controls, Heat Sentry

Models: RME50000

1 32
Download 32 pages 37.94 Kb
Page 9
Image 9
OPERATION

OPERATION

Controls

The hood is operated using the slide controls under the bottom of the hood.

The light switch turns the lamps on and off.

The blower switch :makes it possible to select the motor operating speed. Position 0: motor off.

The pilot lamp lights up whenever the blower is on.

LIGHT

SWITCHBLOWER SWITCH

PILOT

LAMP

fig.11

HEAT SENTRY™

Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.

1)If blower is OFF - it turns blower ON to HIGH speed.

2)If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.

WARNING

The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the main electrical panel.

LIGHT BULBS

This range hood requires two 13 watt G24q-1 Compact Fluorescent lamps (included).

ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE

CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.

To change bulbs:

1.Remove the screw securing the light lens. Fig.12

2.Pull down lens to remove.

3.To replace lamp, grasp lamp at base and pull out to remove. Fig.13

Replace with 13W Fluorescent lamp noted above. CAUTION: BULB MAY BE HOT!

4.Replace the lens and screw.

fig.12

fig.13

9