RV SERIES FORCED DRAFT INDIRECT WATER HEATERS (RV500 - RV800)
EFFECTIVE DATE: | 7/24/03 |
REPLACES: 4/18/01
NOTES:
1.ALL DIMENSIONS ARE IN INCHES. THOSE IN PARENTHESES ARE CENTIMETERS.
2.LOCATION DIMENSIONS
ARE ALL ±1/2".
3. GAS TRAIN, CONTROL AND |
BURNER CONFIGURATION WILL |
VARY DEPENDING ON JOB |
SPECIFICATIONS & CONDITIONS. |
4. DIMENSIONS ARE SUBJECT |
TO CHANGE WITHOUT NOTICE. |
CONSULT FACTORY FOR |
CERTIFIED DIMENSIONS. |
5. ALL FLANGES ARE 150# |
UNLESS OTHERWISE NOTED. |
6. SEE FORMS 1594 AND 1595 |
FOR FLOW RATES AND PRESS. |
DROPS OF 2 AND 4 PASS |
HEAT EXCHANGERS. |
20"
(50.8)
50"
(127.0)
9 1/4"
(23.5)
D
A
25 1/2"
(64.8)
B
C
H
4 1/2" | DETAIL 1 | |
| ||
2 1/8" | 1/2" | |
NPT | ||
| ||
3" NPT | DRAIN | |
4 PASS EXCH. HEAD (STD.) |
| |
(SEE NOTE #6) |
| |
| 4" NPT |
6 1/4"
2 PASS EXCH. HEAD (OPT.)
(SEE NOTE #6)
48" (121.9)
BURNER
SERVICE AREA
|
| PLAN VIEW |
|
| G |
14 | 3 | SUPPLY |
| 5 |
9"
(22.86) | 32" | MINIMUM TUBE |
| ||
| (81.3) | REMOVAL CLEARANCE |
|
|
4
20
16
(SEE DETAIL 1)
18
15
J1
17
90"
(228.6)
87 1/2"
(222.3)
STOP
VALVE
7
33 1/2"
(85.1)
10
J2
2
16
(SEE DETAIL 1)
G
RETURN
9
13
80 1/8"
(203.5)
19 | REAR VIEW |
|
12 | 6 | LEFT SIDE VIEW | FRONT VIEW |
|
1.PROBE TYPE L.W.C.O.-
2.FORCED DRAFT BURNER
3.RELIEF VALVE
4.EXPANSION TANK (LOOSE)
5.CONTROL TAPPINGS 3/4" NPT
6.JACKET ACCESS PANELS
7.PRESS./TEMP. GAUGE
8.CLNOUT./INSP.
9.ELEC. ENCLOSURE-
10.VENT/EXP. TANK CONN. 1" NPT
12.FILL VALVE
13.OIL PUMP LOCATION
14.LIFTING LUGS
15.DRAIN CONNECTION 2" NPT
16.INDIRECT HEAT EXCHANGER
17.HEIGHT OVER SUPPLY
18.FLAME OBSERVATION PORT
19.COMB. CHAMBER DRAIN 1" NPT
20.DRAIN VALVE (BY OTHERS)
BOILER MODEL | RV500WT | RV550WT | RV600WT | RV700WT | RV800WT | |
|
|
|
|
|
| |
130 1/4" | 143 1/4" | 152 3/4" | 175 1/4" | 197 3/4" | ||
(330.8) | (363.9) | (388.0) | (445.1) | (502.3) | ||
| ||||||
|
|
|
|
|
| |
18 3/4" | 18 3/4" | 18 3/4" | 20 3/4" | 20 3/4" | ||
(47.6) | (47.6) | (47.6) | (52.7) | (52.7) | ||
|
|
|
|
|
| |
16" | 16" | 16" | 20" | 20" | ||
(40.6) | (40.6) | (40.6) | (50.8) | (50.8) | ||
|
|
|
|
|
| |
163" | 175 3/4" | 185 1/4" | 214 1/2" | 237 1/4" | ||
(414.0) | (446.4) | (470.5) | (544.8) | (602.6) | ||
|
|
|
|
|
| |
6" FLG | 6" FLG | 6" FLG | 6" FLG | 6" FLG | ||
(152) | (152) | (152) | (15.2) | (15.2) | ||
|
|
|
|
|
| |
CONSULT FACTORY FOR BURNER EXTENSION APPLICATIONS |
| |||||
|
|
|
|
|
| |
75" | 75" | 88" | 101" | 101" | ||
(1905) | (1905) | (223.5) | (256.5) | (256.5) | ||
75" | 88" | 88" | 101" | 114" | ||
(1905) | (223.5) | (223.5) | (256.5) | (289.6) | ||
|
|
|
|
|
|
BRYAN BOILERS
783 NORTH CHILI AVE PERU, INDIANA 46970
ORDER NO.: |
|
|
|
ORDER REV. NO.: |
|
|
|
FORM NO.: | 1770 |