BRYAN BOILERS
RV SERIES FORCED DRAFT INDIRECT WATER HEATERS
Form # >> 1770 Date >> 9/5/2003
BOILER MODEL |
| RV500 | RV550 | RV600 | RV700 | RV800 |
INPUT | MBH | 5,000 | 5,500 | 6,000 | 7,000 | 8,000 |
| (KW) | 1,465.0 | 1,611.5 | 1,758.0 | 2,051.0 | 2,344.0 |
OUTPUT* | MBH | 4,000 | 4,400 | 4,800 | 5,600 | 6,400 |
| (KW) | 1,172.0 | 1,289.2 | 1,406.4 | 1,640.8 | 1,875.2 |
BOILER HORSEPOWER | HP | 119 | 131 | 143 | 167 | 191 |
| (KW) | 1,171.0 | 1,288.1 | 1,405.2 | 1,639.4 | 1,873.6 |
TUBE DIAMETER | INCHES | 1.50 | 1.50 | 1.50 | 1.50 | 1.50 |
| (CM) | 3.81 | 3.81 | 3.81 | 3.81 | 3.81 |
NUMBER OF TUBES |
| 67 | 75 | 81 | 95 | 109 |
PRESSURE VESSEL |
|
|
|
|
|
|
VOLUME | GAL | 200 | 216 | 236 | 278 | 309 |
| (L) | 757.0 | 817.6 | 893.3 | 1,052.2 | 1,169.6 |
HEATING SURFACE | SQ FT | 597 | 668 | 722 | 847 | 973 |
| (SQ M) | 55.5 | 62.1 | 67.1 | 78.7 | 90.4 |
INDIRECT HEAT EXCHANGER |
|
|
|
|
|
|
HEAT EXCHANGER #1 | INCHES | 66 | 79 | 79 | 92 | 92 |
(CM) | 167.6 | 200.7 | 200.7 | 233.7 | 233.7 | |
HEAT EXCHANGER #2 | INCHES | 66 | 66 | 79 | 92 | 105 |
(CM) | 167.6 | 167.6 | 200.7 | 233.7 | 266.7 | |
OPERATING WEIGHT | LBS | 11,167 | 12,151 | 13,138 | 15,028 | 16,811 |
| (KG) | 5,065.5 | 5,511.6 | 5,959.2 | 6,816.6 | 7,625.5 |
SHIPPING WEIGHT | LBS | 9,500 | 10,350 | 11,170 | 12,710 | 14,235 |
| (KG) | 4,309.2 | 4,694.8 | 5,066.7 | 5,765.3 | 6,457.0 |
RELIEF VALVE TYPICAL - 30 PSIG (206.8 KPA) |
|
|
|
| ||
QUANTITY |
| (2) 740 | (2) 740 | (2) 740 | (2) 740 | (2) 740 |
SIZE | INCHES | 2 x 2½ | 2 x 2½ | 2 x 2½ | 2 x 2½ | 2 x 2½ |
| (CM) | 5.08 x 6.35 | 5.08 x 6.35 | 5.08 x 6.35 | 5.08 x 6.35 | 5.08 x 6.35 |
MBH | 10,500 | 10,500 | 10,500 | 10,500 | 10,500 | |
| (KW) | 3,076.5 | 3,076.5 | 3,076.5 | 3,076.5 | 3,076.5 |
RELIEF VALVE TYPICAL - 125 PSIG (861.8 KPA) |
|
|
|
| ||
QUANTITY |
| (1) 174A | (2) 174A | (2) 174A | (2) 174A | (2) 174A |
SIZE | INCHES | 1½ x 1½ | 1¼ x 1¼ | 1¼ x 1¼ | 1¼ x 1¼ | 1¼ x 1¼ |
| (CM) | 3.81 x 3.81 | 3.17 x 3.17 | 3.17 x 3.17 | 3.17 x 3.17 | 3.17 x 3.17 |
MBH | 6,460 | 10,740 | 10,740 | 10,740 | 10,740 | |
| (KW) | 1,892.8 | 3,146.8 | 3,146.8 | 3,146.8 | 3,146.8 |
*Output based on nominal 80% of input. Actual combustion efficiencies will vary and are fuel dependant.
(#) - - Indicates length of exchanger.