BRYAN BOILERS
DR SERIES FORCED DRAFT
STEAM BOILERS REVERSE CONSTRUCTION
Form # >> 2178 Date >> 2/20/04
BOILER MODEL |
| DR250 | DR350 | DR450 | DR650 | DR850 | ||
INPUT | MBH | 250 | 350 | 450 | 650 | 850 | ||
| (KW) | 73.2 | 102.5 | 131.8 | 190.4 | 249.0 | ||
OUTPUT | MBH | 200 | 280 | 360 | 520 | 680 | ||
| (KW) | 58.6 | 82.0 | 105.5 | 152.4 | 199.2 | ||
BOILER HORSEPOWER | HP |
| 6 | 8 | 10 | 15 | 20 | |
| (KW) | 58.6 | 82.0 | 98.0 | 147.0 | 196.0 | ||
TUBE DIAMETER | INCHES | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | ||
| (CM) | 2.54 | 2.54 | 2.54 | 2.54 | 2.54 | ||
NUMBER OF TUBES |
| 18 | 18 | 18 | 29 | 29 | ||
PRESSURE VESSEL |
|
|
|
|
|
|
| |
VOLUME | GAL | 31 | 31 | 31 | 45 | 45 | ||
| (L) | 117.3 | 117.3 | 117.3 | 170.3 | 170.3 | ||
HEATING SURFACE | SQ FT | 66 | 66 | 66 | 103 | 103 | ||
| (SQ M) | 6.1 | 6.1 | 6.1 | 9.6 | 9.6 | ||
STEAM OUTPUT* |
|
|
|
|
|
|
| |
| LBS/HR | 206 | 288 | 371 | 536 | 701 | ||
| (KG/HR) | 93.4 | 130.6 | 168.3 | 243.1 | 318.0 | ||
OPERATING WEIGHT | LBS | 1,408 | 1,408 | 1,408 | 2,025 | 2,025 | ||
| (KG) | 638.9 | 638.9 | 638.9 | 918.6 | 918.6 | ||
SHIPPING WEIGHT | LBS | 1,150 | 1,150 | 1,150 | 1,650 | 1,650 | ||
| (KG) | 521.6 | 521.6 | 521.6 | 748.4 | 748.4 | ||
RELIEF VALVE TYPICAL - 15 PSIG (103.4 KPA) |
|
|
|
|
| |||
QUANTITY |
|
| A | (1) | (1) | (1) | (1) | |
|
| v | ||||||
SIZE | INCHES |
| a | |||||
N | i | |||||||
|
|
|
|
|
| |||
| (CM) | o | l | 3.175 x 3.175 | 3.175 x 3.175 | 3.175 x 3.175 | 3.175 x 3.175 | |
| t | a | ||||||
|
|
|
|
|
| |||
MBH |
| b | 1,200 | 1,200 | 1,200 | 1,200 | ||
| l | |||||||
|
|
|
|
|
|
| ||
| (KW) |
| e | 351.6 | 351.6 | 351.6 | 351.6 | |
|
|
| ||||||
RELIEF VALVE TYPICAL - 150 PSIG (1034.0 KPA) |
|
|
|
|
| |||
QUANTITY |
| (1) 6021DC01 | (1) 6021DC01 | (1) 6021DC01 | (1) 6021DC01 | (1) 6021DC01 | ||
SIZE | INCHES | 1/2 x 3/4 | 1/2 x 3/4 | 1/2 x 3/4 | 1/2 x 3/4 | 1/2 x 3/4 | ||
| (CM) | 1.27x1.905 | 1.27x1.905 | 1.27x1.905 | 1.27x1.905 | 1.27x1.905 | ||
MBH | 925 | 925 | 925 | 925 | 925 | |||
| (KW) | 271.0 | 271.0 | 271.0 | 271.0 | 271.0 |
* Output based on nominal 80% of input. Actual combustion efficiencies will be higher and fuel dependent.