Bryant 331JAV warranty AIR DELIVERY- CFM With Filter, Installation

Models: 331JAV

1 4
Download 4 pages 14.45 Kb
Page 4
Image 4
AIR DELIVERY— CFM (With Filter)

AIR DELIVERY— CFM (With Filter)

UNIT

BLOWER

 

 

 

EXTERNAL STATIC PRESSURE (IN. WC)

 

 

 

 

 

 

 

 

 

 

 

SIZE

MOTOR HP

SPEED

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

 

 

High

1435

1385

1320

1265

1195

1145

1080

1000

036060

1/3 PSC

Med-High

1195

1165

1145

1105

1070

1015

955

885

Med

1030

1020

1010

985

955

915

860

790

 

 

Med-Low

900

890

875

855

835

795

755

690

 

 

Low

705

700

690

675

655

625

580

525

 

 

High

1855

1765

1710

1665

1580

1570

1410

1310

048080

1/2 PSC

Med-High

1595

1570

1530

1485

1410

1355

1280

1200

Med

1355

1345

1305

1270

1220

1170

1110

1025

 

 

Med-Low

1170

1170

1140

1110

1075

1025

965

890

 

 

Low

880

865

855

830

805

755

720

655

 

 

High

2235

2185

2110

2030

1950

1835

1700

1540

060100

3/4 PSC

Med-High

1995

1970

1915

1845

1765

1680

1545

1415

Med

1735

1735

1675

1625

1565

1480

1370

1265

 

 

Med-Low

1510

1500

1485

1455

1400

1320

1230

1130

 

 

Low

1145

1140

1125

1115

1100

1085

1045

990

INSTALLATION

This unit is certified for downflow installation only. See Installation Manual for

important installation instructions.

MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION

This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft

(0-3,050m).

This furnace is approved for DOWNFLOW installations only.

1"

An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications.

This furnace is for indoor installation in a building constructed on site.

This furnace may be installed on combustible flooring in alcove or closet at minimum clearance from combustible material.

This furnace may be used with a Type B-1 Vent and may be vented in common with other gas-fired appliances.

For installation on non-combustible

 

floors only. For installation on

 

combustible flooring only when

0"

B A C K

 

E

I

D

S

 

1" #

TOP / PLENUM

 

 

E

1" #

 

 

 

D

 

E

S

I

 

 

 

 

 

 

C

 

 

 

 

A

 

 

 

 

N

 

 

 

 

R

 

 

 

 

U

 

 

 

 

F

T

 

 

 

 

 

 

 

 

N

 

 

 

O

 

 

 

R

 

 

 

 

F

 

 

 

 

 

 

S E

R V I

 

F R O

 

 

C E 30"

N T

 

 

 

 

 

MIN

##

Ø

installed on special base, Part No.

KGASB0201ALL, Coil Assembly,

Part No. CD5 or CK5, or Coil

Casing, Part No. KCAKC.

# For furnaces wider than 14.25

inches (362mm) may be 0 inches.

Ø18 inches front clearance required

for alcove.

##For single wall vent type 6 inches.

Clearance in inches.

BOTTOM

E (LIT)

 

REV.

 

1"

Vent Clearance to combustibles:

-101

For Single Wall vents 6 inches (6 po).

322567

 

For Type B-1 vent type 1 inch (1 po).

 

 

 

 

 

 

 

A97620

 

 

 

 

 

 

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

 

 

 

 

 

 

UNIT MUST BE INSTALLED IN ACCORDANCE

 

 

 

 

 

 

 

 

 

 

 

 

WITH INSTALLATION INSTRUCTIONS

 

 

 

 

 

—4—

 

Cancels: PDS 331J.60.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

© 1999 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls., IN 46231

PRINTED IN U.S.A.

Catalog No. 5233-103 10-99

Page 4