Bryant 352MAV, 350MAV, 355MAV manual Steps for Starting Your Furnace

Models: 355MAV 352MAV 350MAV

1 12
Download 12 pages 42.74 Kb
Page 5
Image 5

the floor. If you smell gas, STOP! Follow “B” in the safety information above on this furnace label. If you don’t smell gas, go to the next step.

If a suspected malfunction occurs with your gas control system, such as the burners not lighting when they should, refer to the shutdown proce- dures on inside of main furnace door, or in the “Shutting Down Your Fur- nace” section and call your dealer as soon as possible.

!WARNING

If overheating occurs or the gas valve fails to shut off the gas supply, turn off the exter- nal manual gas valve to the furnace BEFORE turning off the electrical supply. (See Fig. 9.) Failure to follow this warn- ing could result in a fire or ex- plosion, and personal injury/ death or property damage.

CHECK AIR FILTER: Before attempting to start your furnace, be sure the furnace air filter is clean and in place. See “Performing Routine Main- tenance” section in this manual.

Then proceed as follows:

STEPS FOR STARTING YOUR FURNACE

1.Set your room thermostat to the lowest temperature setting. (See Fig. 8.)

®

8a

CL

O

S

E

9

10

2.Close the external manual gas valve. (See Fig. 9.)

3.Turn OFF electrical supply to the furnace. (See Fig. 10.)

4.Remove main furnace door. (See Fig. 11.)

5.The gas valve will have a control switch to turn OFF or ON. Turn control switch on the gas control to the OFF position and wait 5 min- utes. (See Fig. 12 or 13.) Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” on furnace label. If you don’t smell gas, go to next step.

6.After waiting 5 minutes, turn con- trol switch on the gas valve to the ON position. (See Fig. 14 or 15.)

7.Replace main furnace door. (See Fig. 16.)

11

For 352MAV and 355MAV

12

OFF

ON

or

 

For 340MAV and 350MAV

13

For 352MAV and 355MAV

 

14

OFF

ON

 

or

For 340MAV and 350MAV

15

8.Turn ON electrical supply to the furnace and wait 1 minute.

(See Fig. 17.)

9.Open the external manual gas valve. (See Fig. 18.)

10.Set room thermostat to a tempera- ture slightly above room tempera- ture. This will automatically signal the furnace to start.

11.When the furnace receives the start signal, the inducer is started. When the pressure switch senses that there is sufficient combustion air, the hot surface igniter is ener- gized. After the hot surface igniter is heated for 17 seconds, the gas valve permits gas to flow to the main burners. After ignition and a time delay of about 60 sec, the fur- nace blower will start. Variable- capacity furnaces start at low

speed until the control makes the

5

Page 5
Image 5
Bryant 352MAV, 350MAV, 355MAV manual Steps for Starting Your Furnace

355MAV, 352MAV, 350MAV specifications

The Bryant 355MAV is a remarkable model that stands out in the HVAC (heating, ventilation, and air conditioning) industry for its efficiency, reliability, and advanced technology. This unit is specifically designed to provide homeowners with excellent comfort while maintaining energy efficiency, making it an ideal choice for residential applications.

One of the standout features of the Bryant 355MAV is its variable speed compressor. This technology allows the system to adjust its cooling output based on the current temperature needs of the home. By operating at multiple speed levels, the compressor can maintain a more consistent indoor climate while using significantly less energy than traditional single-speed systems. This capability translates to lower energy bills and enhanced comfort.

Additionally, the Bryant 355MAV integrates an advanced control system that offers precise temperature regulation. Homeowners can easily set their desired indoor conditions, and the thermostat will communicate with the system to ensure optimal performance. This smart technology not only enhances comfort but also extends the lifespan of the unit by preventing unnecessary strain during operation.

The 355MAV also features significant advancements in sound reduction technology. Designed with noise-absorbing materials and a quiet operation mode, this unit ensures that indoor comfort is maintained without the disruption of loud operational sounds. This makes it a perfect choice for residential settings, particularly in areas where noise sensitivity is a concern.

Energy efficiency is another key characteristic of the Bryant 355MAV. The unit is certified with a high Seasonal Energy Efficiency Ratio (SEER) rating, which means it meets strict energy consumption standards. This not only reflects its eco-friendliness but also contributes to significant savings on utility bills over time.

Moreover, the Bryant 355MAV uses environmentally friendly refrigerants that comply with EPA regulations, further solidifying its commitment to sustainability. This, combined with durable construction and a reliable warranty, ensures that homeowners can expect lasting performance from the system.

In conclusion, the Bryant 355MAV offers an impressive array of features, including a variable speed compressor, advanced control systems, sound reduction technology, and high energy efficiency. These characteristics make it an exceptional option for those seeking a reliable and efficient HVAC solution in their homes. With its commitment to comfort, savings, and sustainability, the Bryant 355MAV continues to be a popular choice among homeowners looking to enhance their indoor environments.