Bryant 355CAV Combustion Area And Vent System, Replace Furnace Door, Furnace Air Filter Table

Models: 355CAV

1 14
Download 14 pages 23.93 Kb
Page 10
Image 10
Fig. 30 - Replace Furnace Door

A05088

Fig. 30 - Replace Furnace Door

A06192

Fig. 31 - Replace Side Filter Cabinet Door

5.If washable filter, wash filter (if dirty) in sink, bathtub, or outside with a garden hose. Always use cold tap water. A mild liquid detergent may be used if necessary. Spray water through filter in the opposite direction of airflow. Allow filter to dry.

6.Reinstall clean air filter.

7.Reinstall filter retainer (for blower compartment locations only).

8.Replace blower access panel and main furnace door (Fig. 29 and 30.) or filter cabinet door. (Fig. 31 and 32.)

9.Turn on electrical supply to furnace.

If your furnace air filter needs to be replaced, be sure to use a factory-authorized filter of the same size that was originally supplied. Use the filter tables and compare your furnace size with the proper filter size.

A06193

Fig. 32 - Replace Bottom Filter Cabinet Door

FURNACE AIR FILTER TABLE

AIR FILTER LOCATED IN BLOWER COMPARTMENT

FURNACE

 

 

FILTER SIZE --- IN (mm)

 

 

CASING

 

 

 

FILTER

 

 

 

 

 

 

 

 

WIDTH

 

 

 

 

 

 

 

 

TYPE

 

Side Return†*

 

Bottom Return*

 

IN (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17–1/2

 

(1) 16 X 25 X 3/4

 

(1) 16 X 25 X 3/4

 

Washable

(445)

 

(406 X 635 X 19)

 

(406 X 635 X 19)

 

 

 

 

 

21 (533)

 

(1) 16 X 25 X 3/4

 

1) 20 X 25 X 3/4

 

Washable

 

(406 X 635 X 19)

 

(508 X 635 X 19)

 

 

 

 

 

 

24–1/2

 

(1 or 2) 16 X 25 X

 

(1) 24 X 25 X 3/4

 

Washable

 

 

3/4

 

 

(622)

 

 

 

(610 X 635 X 19)

 

 

(406 X 635 X 19)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR FILTER LOCATED IN FILTER CABINET

FILTER CABINET

 

 

FILTER

 

FILTER

HEIGHT --- IN (mm)

 

SIZE --- IN (mm)

 

 

TYPE

16 (406)

 

 

(1) 16 x 25 x 3/4*

 

Washable

 

 

(406 X 635 X 19)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) 20 x 25 x 3/4*

 

 

 

 

 

 

 

(508 X 635 X 19)

 

 

 

20 (508)

 

 

 

 

or

 

Washable

 

 

 

 

(1) 20 x 25 x 4---5/16

 

 

 

 

 

 

 

 

 

 

 

 

(508 X 635 X 110)

 

 

 

 

 

 

 

(1) 24 x 25 x 3/4*

 

 

 

 

 

 

 

(610 X 635 X 19)

 

 

 

24 (610)

 

 

 

or

 

Washable

 

 

 

 

(1) 24 x 25 x 4---5/16

 

 

 

 

 

 

 

 

 

 

 

 

(610 X 635 X 110)

 

 

 

*Factory ---provided with the furnace. Filters may be field modified by

cutting filter material and support rods (3) in filters.

 

 

{Upflow only. Alternate sizes and additional filters may be ordered from your dealer.

!WARNING

PERSONAL INJURY HAZARD

Failure to follow this warning could result in personal injury.

Use care when cutting support rods in filters to protect against flying pieces and sharp rod ends. Wear safety glasses, gloves, and appropriate protective clothing.

COMBUSTION AREA AND VENT SYSTEM

Visually inspect the combustion area and vent system before each heating season. Make sure that all PVC pipes leading into the combustion area and vent are free from any cracks and sags.

10

Page 10
Image 10
Bryant 355CAV owner manual Combustion Area And Vent System, Replace Furnace Door, Replace Side Filter Cabinet Door