LED CODE |
| SERVICE | |
| STATUS |
| |
CONTINUOUS OFF - Check for 115VAC at L1 and L2, and 24VAC at | |||
CONTINUOUS ON - | |||
Control has 24V power. |
RAPID FLASHING - Line voltage (115V) polarity reversed. If twinned, refer to twinning kit instructions.
EACH OF THE FOLLOWING STATUS CODES IS A TWO DIGIT NUMBER WITH THE FIRST DIGIT DETERMINED BY THE NUMBER OF SHORT FLASHES AND THE SECOND DIGIT BY THE NUMBER OF LONG FLASHES.
11NO PREVIOUS CODE - Stored status codes are erased when power (115V or 24V) to control is interrupted or 48 hours after each fault is cleared.
12BLOWER ON AFTER POWER UP (115V or 24V) - Blower runs for 90 seconds, if unit is powered up during a call for heat
13LIMIT OR FLAME
14IGNITION LOCKOUT - Control will
21GAS HEATING LOCKOUT - Control will NOT auto reset.
Check for: - Stuck gas valve relay on control or miswire to gas valve circuit.
22ABNORMAL
-
23PRESSURE SWITCH DID NOT OPEN Check for:
- Obstructed pressure tubing. | - Defective pressure switch |
| (stuck closed). |
24 SECONDARY VOLTAGE FUSE IS OPEN
Check for: - Short circuit in secondary voltage (24V) wiring.
31PRESSURE, DRAFT SAFEGUARD,
BLOCKED VENT SHUTOFF (when used) SWITCH DID NOT CLOSE OR
REOPENED - If open longer than five minutes, inducer shuts off for 15 minutes before retry. Check for:
- Proper vent sizing and condensate pitch | - Inadequate Combustion air supply. |
or sag. | - Low inducer voltage. |
- Vent restriction or high winds. | - Disconnected or obstructed |
- Defective inducer motor or start capacitor. | pressure tubing. |
- Defective pressure switch or connections. If it opens after trial for ignition period, blower will come on for 90 second recycle delay.
33 LIMIT OR FLAME
minutes,code changes to #13. Check for: |
|
- Defective blower motor or start capacitor. | - Dirty filter or restricted duct system. |
- Loose blower wheel. | - Defective switch or connections. |
-Inadequate Combustion air supply Flame
-Open Flame
34IGNITION PROVING FAILURE - Control will try three more times before a lockout #14 occurs. If flame signal lost after trial for ignition period, blower will
come on for 90 second recycle delay. Check for:
-Oxide buildup on flame sensor (clean with fine sandpaper).
-Proper flame sense microamps (.5 microamps D.C. minimum).
-Gas valve turned off. - Manual
-Green wire MUST be connected to furnace sheet metal.
-Inadequate flame carryover or rough ignition.
COMPONENT TEST
To initiate the component test sequence,shut OFF the room thermostat or disconnect the "R" thermostat lead. Briefly short the TEST terminal to the 'Com 24V' terminal. Status LED will flash code and then turn ON the inducer motor. The inducer motor will run for the entire component test. The hot surface ignitor, blower
9 | 6 | 3 |
8 | 5 | 2 |
7 | 4 | 1 |
STATUS | TEST | HUM | 24V | Y | R | G |
|
| Com W |