Your combination heating/cooling unit is equipped with an automatic direct spark ignition and power combustion blower.

WARNING: Do not attempt to light by hand; per- sonal injury may result.

TO LIGHT UNIT

DANGER:

1.Do not turn off the electrical power to unit without ®rst turning off the gas supply.

2.Before attempting to start the gas heating section, familiarize yourself with all the procedures that must be followed.

If you do not follow these instructions exactly, a ®re or explosion may result, causing property damage, injury, or loss of life.

Refer to Fig. 1. See Fig. 2 for location of gas valve. Refer to Fig. 3 while proceeding with the following steps.

I. Step 1

Set the temperature selector on room thermostat to the low- est temperature setting and set system switch to HEAT.

II. Step 2

Close the external manual shutoff valve.

III. Step 3

Turn off the electrical supply to the unit.

IV. Step 4

Remove the front access panel with a 5¤16-in. nut driver.

V. Step 5

Move the selector switch on the internal gas valve to the OFF position and wait 5 minutes.

VI. Step 6

Move the selector switch on the internal gas valve to the ON position.

VII. Step 7

Replace the front access panel.

VIII. Step 8

Turn on the electrical supply to unit.

IX. Step 9

Open the external manual shutoff valve.

X. Step 10

Set the temperature selector on room thermostat slightly above room temperature to start unit. The induced-draft combustion- air fan will start. Main gas valve will open and main burners should ignite within 5 seconds. If the burner does not light within 5 seconds, the ignition module will go into a Retry mode after a period of approximately 22 seconds (following the 5-second ignition period).

If the burners do not light within 15 minutes of the initial call for heat, there is a lockout.

XI. Step 11

Set the temperature selector on room thermostat to desired setting.

FRONT

ACCESS

PANEL

Fig. 1 Ð Gas Heating/Electric Cooling Unit

WARNING:

1.If the main burners fail to light, or the blower fails to start, shut down gas heating section and call your dealer for service.

2.Never attempt to manually light the main burners on unit with a match, lighter, or any other ¯ame. If the electric sparking device fails to light the main burners, refer to the following shutdown proce- dures, then call your dealer as soon as possible.

Failure to follow these requirements could result in serious personal injury.

TO SHUT UNIT OFF

WARNING: Do not turn off the electrical power to unit without ®rst turning off the gas supply.

Failure to follow these procedures can result in serious ®re or personal injury.

NOTE: If unit is being shut down because the heating sea- son has ended, make sure to turn on power to cooling system.

If unit is being shut down because of a malfunction, call your dealer as soon as possible.

Should overheating occur or the gas supply fail to shut off, shut off the manual gas valve to the unit before shutting off the electrical supply.

Do not use this unit if any part has been under water. Im- mediately call a quali®ed service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.

Refer to Fig. 4 while proceeding with the following steps.

I. Step 1

Set the temperature selector on room thermostat to lowest temperature setting and set system switch to OFF.

II. Step 2

Close the external manual shutoff valve.

Ð2Ð

Page 2
Image 2
Bryant 583A manual To Light Unit, To Shut Unit OFF

583A specifications

The Bryant 583A is a cutting-edge gas furnace designed for both efficiency and comfort, making it an ideal heating solution for residential applications. This model is particularly known for its exceptional performance and innovative technology, resulting in lower energy bills and a more consistent indoor environment.

One of the standout features of the Bryant 583A is its high-efficiency operation, boasting an AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%. This means that a significant portion of the fuel consumed is converted into usable heat, making it an environmentally friendly choice that reduces energy waste. The design employs a two-stage heating operation, which allows the furnace to adjust its output according to the heating demands of the home, providing balanced warmth while minimizing energy consumption.

Built with advanced technology, the Bryant 583A includes a variable-speed blower motor that enhances comfort by distributing heated air more evenly throughout the home. This feature not only improves air circulation but also promotes quieter operation compared to standard single-speed blowers. The intelligent control system of the furnace permits compatibility with smart thermostats, which further enhances energy efficiency and user convenience.

Another notable characteristic of the Bryant 583A is its durability. Constructed with high-quality materials, this furnace is designed to withstand the rigors of continuous operation and to provide reliable service throughout its lifespan. Additionally, it features a heavy-duty heat exchanger that ensures optimal heat transfer while reducing the risk of breakdowns.

The Bryant 583A also prioritizes safety with features such as an automatic shut-off, which activates in the event of a malfunction, protecting both the system and the home. Additionally, its compact design allows for easy installation in a variety of spaces, making it a versatile choice for different home layouts.

In summary, the Bryant 583A is a remarkable gas furnace that combines high-efficiency performance, cutting-edge technology, and reliability. With its two-stage heating operation, variable-speed blower motor, and robust safety features, it caters to homeowners seeking both comfort and cost savings during the colder months. As a trusted name in heating solutions, Bryant continues to lead the way in delivering products that enhance home comfort while prioritizing energy efficiency and durability.