Bryant 594D warranty DETAILED COOLING CAPACITIES* Continued

Models: 594D

1 24
Download 24 pages 55.28 Kb
Page 16
Image 16

DETAILED COOLING CAPACITIES* Continued

EVAPORATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSER ENTERING AIR TEMPERATURES °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

 

 

85

 

 

 

 

 

95

 

 

 

 

105

 

 

 

 

115

 

 

 

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

Total

 

 

Capacity

 

Total

Capacity

 

Total

 

Capacity

Total

 

Capacity

 

Total

 

 

 

 

 

MBtuh†

 

 

MBtuh†

 

 

MBtuh†

 

 

MBtuh†

 

MBtuh†

 

 

 

 

 

 

System

 

 

System

 

System

 

System

 

 

System

CFM

EWB

 

Total

 

Sens‡

Kw**

 

Total

 

Sens‡

 

Kw**

Total

Sens‡

 

Kw**

Total

 

Sens‡

Kw**

 

Total

 

Sens‡

 

Kw**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

594D042-E Outdoor Section With CC5A/CD5AA048 Indoor Section

 

 

 

 

 

 

 

 

 

72

 

45.8

 

22.5

 

3.61

 

44.0

 

21.9

 

3.99

42.3

21.2

 

4.42‘

40.4

 

20.5

4.9

 

38.5

 

19.8

 

5.44

1225

 

67

 

42.0

 

28.4

 

3.57

 

40.4

 

27.8

 

3.95

38.7

27.1

 

4.38

37.1

 

26.4

4.8

 

35.3

 

25.7

 

5.40

 

62

 

38.4

 

34.2

 

3.54

 

36.9

 

33.5

 

3.91

35.4

32.7

 

4.34

33.8

 

32.0

4.8

 

32.3

 

31.1

 

5.36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

 

36.6

 

36.6

 

3.53

 

35.4

 

35.4

 

3.91

34.2

34.2

 

4.33

33.0

 

33.0

4.8

 

31.8

 

31.8

 

5.36

 

 

72

 

46.5

 

23.4

 

3.68

 

44.7

 

22.7

 

4.06

42.8

22.1

 

4.49

40.9

 

21.4

4.9

 

38.9

 

20.7

 

5.51

1400

 

67

 

42.7

 

30.0

 

3.64

 

41.0

 

29.3

 

4.02

39.3

28.7

 

4.45

37.5

 

27.9

4.9

 

35.7

 

27.2

 

5.46

 

62

 

39.1

 

36.4

 

3.61

 

37.5

 

35.5

 

3.98

35.9

34.7

 

4.41

34.4

 

33.8

4.8

 

32.8

 

32.7

 

5.42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

 

37.9

 

37.9

 

3.60

 

36.6

 

36.6

 

3.98

35.4

35.4

 

4.41

34.1

 

34.1

4.8

 

32.7

 

32.7

 

5.43

 

 

72

 

47.0

 

24.3

 

3.75

 

45.1

 

23.6

 

4.13

43.2

22.9

 

4.56

41.3

 

22.2

5.0

 

39.2

 

21.5

 

5.57

1575

 

67

 

43.2

 

31.6

 

3.71

 

41.5

 

30.9

 

4.09

39.7

30.2

 

4.51

37.9

 

29.5

4.9

 

36.1

 

28.8

 

5.53

 

62

 

39.6

 

38.3

 

3.68

 

38.1

 

38.3

 

4.05

36.5

36.3

 

4.48

35.0

 

35.0

4.9

 

33.6

 

33.6

 

5.49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

 

39.0

 

39.0

 

3.67

 

37.7

 

37.7

 

4.05

36.4

36.4

 

4.48

35.0

 

35.0

4.9

 

33.6

 

33.6

 

5.50

 

 

 

 

 

 

 

 

 

Multipliers for Determining the Performance With Other Indoor Sections

 

 

 

 

 

 

 

 

 

Indoor

 

 

 

 

 

 

 

 

 

Cooling

 

 

 

 

Indoor

 

 

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Section

 

 

Size

 

Capacity

 

 

 

Power

 

 

Section

 

Size

 

Capacity

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CC5A/CD5AA

 

 

042

 

 

1.00

 

 

 

 

1.00

 

 

FK4CNF

 

003

 

 

 

1.00

 

 

 

0.95

 

CC5A/CD5AC

 

 

048

 

 

0.99

 

 

 

 

1.00

 

 

 

 

 

 

005

 

 

 

1.02

 

 

 

0.96

 

CC5A/CD5AW

 

 

042

 

 

0.99

 

 

 

 

1.00

 

 

COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE

 

 

 

 

 

 

 

048

 

 

1.00

 

 

 

 

1.00

 

 

CD5AA

 

 

048

 

 

 

1.00

 

 

 

0.93

 

 

CD5AA

 

 

048

 

 

1.00

 

 

 

 

1.00

 

 

CE3AA

 

 

048

 

 

 

1.00

 

 

 

0.94

 

 

CE3AA

 

 

042

 

 

1.00

 

 

 

 

1.00

 

 

CK5A/CK5BA

 

048

 

 

 

1.00

 

 

 

0.93

 

 

 

 

 

 

 

048

 

 

1.01

 

 

 

 

1.00

 

 

COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE

 

 

CF5AA

 

 

048

 

 

1.01

 

 

 

 

1.00

 

 

CD5AA

 

 

048

 

 

 

1.00

 

 

 

0.93

 

 

CK3BA

 

 

042

 

 

1.00

 

 

 

 

1.00

 

 

CE3AA

 

 

048

 

 

 

1.00

 

 

 

0.94

 

 

 

 

 

 

 

048

 

 

1.00

 

 

 

 

1.00

 

 

CK5A/CK5BA

 

048

 

 

 

1.00

 

 

 

0.93

 

CK5A/CK5BA

 

 

042

 

 

1.00

 

 

 

 

1.00

 

 

COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE

 

 

 

 

 

 

 

048

 

 

1.00

 

 

 

 

1.00

 

 

CD5AA

 

 

048

 

 

 

1.00

 

 

 

0.93

 

CK5A/CK5BW

 

 

042

 

 

0.99

 

 

 

 

1.00

 

 

CE3AA

 

 

048

 

 

 

1.00

 

 

 

0.94

 

 

 

 

 

 

 

048

 

 

1.00

 

 

 

 

1.00

 

 

CK5A/CK5BA

 

048

 

 

 

1.00

 

 

 

0.93

 

F(A,B)4AN(F,B,C)

 

042

 

 

1.00

 

 

 

 

1.01

 

 

COILS + 355MAV042080 VARIABLE SPEED FURNACE

 

 

 

 

 

 

 

048

 

 

1.01

 

 

 

 

1.02

 

 

CD5A/CD5BA

 

048

 

 

 

1.00

 

 

 

0.92

 

FC4BN(F,B)

 

 

042

 

 

1.00

 

 

 

 

1.01

 

 

CK5A/CK5BA

 

048

 

 

 

1.00

 

 

 

0.92

 

 

 

 

 

 

 

048

 

 

1.01

 

 

 

 

1.02

 

 

COILS + 355MAV060100 VARIABLE SPEED FURNACE

 

 

FC4BNB

 

 

054

 

 

1.04

 

 

 

 

1.00

 

 

CD5AA

 

 

048

 

 

 

1.00

 

 

 

0.92

 

 

FG3AAA

 

 

048

 

 

1.00

 

 

 

 

1.00

 

 

CK5A/CK5BA

 

048

 

 

 

1.00

 

 

 

0.92

 

 

FK4CNB

 

 

006

 

 

1.04

 

 

 

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 