Bryant CD5A Indoor Coil Pistons, Accessory Empty Coil Casing For Uncased A-Coil, Factor, Unit

Models: CC5A CD5A

1 8
Download 8 pages 1.36 Kb
Page 6
Image 6
NOTES:

NOTES:

1. Formulas:

sensible heat cap.

Leaving db = entering db —

1.09 x CFM

Leaving wb = wb corresponding to enthalpy of air leaving coil (hLWB)

hLWB = hEWB

total capacity (Btuh)

4.5 x CFM

 

where hEWB = enthalpy of air entering coil.

2.Direct interpolation is permissible. Do not extrapolate.

3.Fan motor heat has not been deducted.

4.All data points are based on 10°F superheat leaving coil, and use of thermal expansion valve device.

5.All units have sweat suction tube connection and a liquid tube connection. For 1-1/8-in. system suction tube, 3/4- x 1-1/8-in. suction tube connection adapter is available as accessory.

6.Check-Flo-Rater pistons (sized for matched cooling-only systems). Refer to outdoor unit installation instructions for pistons required for other systems.

7.The CD5A and CC5A coils can be used in any properly designed system using R-22 or Puron® refrigerant.

8.Before using maximum cfm shown in table, check coil static pressure drop to ensure system blower can provide necessary static pressure needed for coil and duct systems.

 

ENTERING AIR DRY BULB TEMPERATURE (°F)

 

 

 

 

 

 

 

 

79

78

77

76

75

Under 75

 

 

 

 

 

 

 

BYPASS

81

82

83

84

84

Above 85

 

 

 

 

 

 

FACTOR

 

 

Correction Factor

 

 

 

 

 

 

 

 

0.10

0.98

1.96

2.94

3.92

4.91

Use formula

0.20

0.87

1.74

2.62

3.49

4.36

shown below

0.30

0.76

1.53

2.29

3.05

3.82

 

 

 

 

 

 

 

 

Interpolation is permissible.

Correction Factor = 1.09 x (1 – BF) x (db – 80)

 

 

INDOOR COIL PISTONS

 

 

 

 

 

 

UNIT

 

FACTORY-INSTALLED INDOOR PISTON SIZE

 

 

 

 

 

CD5AXA018

 

 

52

CC5AXA018

 

 

 

 

 

CD5AXA024, W024

 

 

59

CC5AXA024, W024

 

 

 

 

 

 

 

 

 

 

CD5AXA030, W030

 

 

67

CC5AXA030, W030

 

 

 

 

 

 

 

 

 

 

CD5AXA036, W036

 

 

70

CC5AXA036, W036

 

 

 

 

 

CD5AXA042, W042

 

 

78

CC5AXA042, W042

 

 

 

 

 

 

 

 

 

CD5AXA048, C048, W048

 

84

CC5AXC048, W048

 

 

 

 

 

 

 

 

 

 

CD5AXA060

 

 

90

CC5AXA060

 

 

 

 

 

CD5AXW060

 

 

90

CC5AXW060

 

 

 

 

 

ACCESSORY EMPTY COIL CASING FOR UNCASED A-COIL

 

 

 

 

ACCESSORY PART NO.*

 

NOMINAL CC5A COIL SIZES

DIMENSIONS (In.) W x H x D

 

 

 

 

KCAKC1212ECC

 

A018, A024, A030

14-3/16 x 19 x 21

 

 

 

 

KCAKC1312ECC

 

W024, W030, A036

17-1/2 x 20-1/2 x 21

 

 

 

 

KCAKC1408ECC

 

W036, A042, C048

21 x 22 x 21

 

 

 

 

KCAKC1508ECC

 

W042, W048, A060

24-1/2 x 22 x 21

 

 

 

 

KCAKC1604ECC

 

W060

31-1/2 x 22 x 21

 

 

 

 

 

* Individual casings are sold and shipped in multi-packs as indicated in the 8th and 9th digits.