MODEL NUMBER NOMENCLATURE

HUM

MODEL NUMBER NOMENCLATURE

HUM

BB

LFP

14

18

Product Type

Brand

Model Type

Series

Gallons (Liters) Per Day

Humidifier

Bryant

LFP --- Large Fan Powered

14 --- LFP

LFP --- 18 (68)

 

 

SBP --- Small Bypass

24 --- SBP, LBP, WBP

SBP --- 12 (45)

 

 

LBP --- Large Bypass

10 --- SFP

LBP --- 17 (64)

 

 

SFP --- Small Fan Powered

 

SFP --- 12.8 (48)

 

 

WBP --- Water Saving

 

WBP --- 17 (64)

 

 

Large Bypass

 

 

PHYSICAL DATA

 

 

 

 

 

 

 

 

 

 

MODEL

HUMBBLFP1418

 

HUMBBLBP2417

 

HUMBBWBP2417

 

HUMBBSBP2412

 

HUMBBSFP1016

Gallons

18 (68)

 

17 (64)

 

12 (45)

 

12.8 (48)

(Liters)/Day

 

 

 

 

 

 

 

 

 

 

 

 

Gallons (Liters)/Hr

6 (23)

 

 

3 (11)

 

 

 

3.2 (12)

Type

 

 

 

 

 

 

 

 

 

Airflow

Fan

 

 

 

Bypass

 

 

Fan

Water Flow

Drain Through

 

Sump with Overflow

 

Drain Through

 

Drain

 

 

 

 

 

 

 

 

 

 

General

 

 

 

 

 

 

 

 

 

Water Panel

P110--- 3545

 

P110--- 3545

 

P110--- 4545

 

P110--- 1045

 

324897--- 761

Replacement

(10 packs)

 

(10 packs)

 

(5 --- 2 packs)

 

(10 packs)

 

(10 packs)

Water Panel

 

 

13 x 10 x 1.7

 

 

 

9.9 x 9.6 x 1.7

 

9.7 x 9.2 x 1.2

in (mm)

 

 

 

 

 

 

 

 

(330 x 254 x43)

 

 

 

(251 x 244 x 41)

 

(248 x 235 x 32)

(H x W x D)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Panel

 

 

Quick Release Cover

 

 

Side Door

Access

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Size

18.0 x 16.0 x 10.25

 

15.125 x 14.0 x 10.25

 

12.25 x 14.0 x 10.25

 

12 x 12.5 x 10.18

in (mm)

 

 

 

(457 x 406 x 260)

 

(384 x 356 x 260)

 

(311 x 356 x 260)

 

(305 x 318 x 259)

(H x W x D)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight lbs (kg)

17.1 (7.8)

 

8.0 (4)

 

7.0 (3)

 

10.9 (5)

Water Usage

6 (23)

 

 

3 (11)

 

 

 

3.2 (12)

Gal (liters)/hr)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Control Low---Voltage Solenoid

 

 

 

 

 

 

 

Volts

 

 

 

 

24V--- 60Hz

 

 

 

Amps (Max)

 

 

 

0.5

 

 

 

 

VA (Max)

 

 

 

12

 

 

 

 

Watts

 

 

 

2.3

 

 

 

1.0

High Voltage Cord

 

 

 

 

 

 

 

 

 

Volts

120V--- 1ph--- 60Hz

 

 

 

N/A

 

 

115V--- 1ph--- 60Hz

Amps

0.7

 

 

 

N/A

 

 

1.9

Connections

 

 

 

 

 

 

 

 

 

Water Inlet

 

 

 

1/4--- in. Copper Tubing

 

 

 

Water Drain

 

 

1/2--- in. I.D. plastic hose

 

 

5/8--- in. Tube

Bypass Opening

N/A

 

 

6--- in. round elbow or straight

 

N/A

Duct Opening

14.81 x 14.25

 

9.87 x 12.62

 

9.5 x 9.5

 

11.87 x 11.5

in (mm)

 

 

 

(376 x 362)

 

(251 x 321)

 

(241 x 241)

 

(302 x 292)

(W x H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard Equipment

 

 

 

 

 

 

 

 

 

Water Valve

 

 

 

 

Solenoid, 24VAC

 

 

 

 

Thermal Protected

 

 

 

 

 

 

 

Thermal Protected

Motor

120VAC

 

 

 

N/A

 

 

 

 

 

 

 

115VAC, 25MH

 

(0.014HP = 1/70 HP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay

DPST 24VAC*

 

 

 

N/A

 

 

SPST 24VDC to AC

Humidistat

24V

 

 

24V (not included)

 

 

24V

Saddle Valve

 

 

 

 

Standard

 

 

 

 

Damper

N/A

 

 

 

Standard

 

 

N/A

Template

 

 

 

Installation Sheet Included

 

 

 

Accessories

 

 

 

 

 

 

 

 

 

HumidiTract

 

 

 

 

KUAW0101CAC

 

 

 

Automatic Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current Sensing

 

 

P110--- 0050

 

 

N/A

Relay

 

 

 

 

 

 

 

 

 

 

 

 

 

*Field---supplied part no. HN61KQ120