Bryant HUMBBWBP2417, HUMBBLBP2417, HUMBBSBP2412, HUMBBLFP1418 manual Maximum Moisture Requirements

Models: HUMBBLFP1418 HUMBBSBP2412 HUMBBLBP2417 HUMBBWBP2417

1 6
Download 6 pages 43.12 Kb
Page 4
Image 4
MAXIMUM MOISTURE REQUIREMENTS*

HUM

RECOMMENDED RELATIVE HUMIDITY BY OUTDOOR TEMPERATURE

OUTDOOR TEMP

OUTDOOR RELATIVE HUMIDITY

INDOOR RELATIVE HUMIDITY

MAX RECOMMENDED INDOOR

_F (_C)

(%)

(%) W/O HUMIDIFIER*

RELATIVE HUMIDITY{

--- 10 (--- 23)

30 to 70

1 to 2

20 (Lo)

0 (--- 18)

30 to 70

2 to 4

25

10 (--- 12)

30 to 70

3 to 6

30

20 (--- 7)

30 to 70

4 to 10

35

30 (--- 1)

30 to 70

6 to 15

40 (Med)

*Indoor relative humidity level when outdoor air is heated to 72_F/22_C. { As stipulated by the Air Conditioning Contractors of America.

INDOOR RELATIVE HUMIDITY LIMIT FOR NO WINDOW CONDENSATION

(Indoor Air at 74_F/23_C Dry Bulb)

OUTDOOR TEMPERATURE

SINGLE PANE WINDOWS (%)

DOUBLE PANE WINDOWS (%)

_F (_C)

 

 

40 (4)

39

59

30 (--- 1)

29

50

20 (--- 7)

21

43

10 (--- 12)

15

36

0 (--- 18)

10

30

--- 10 (--- 23)

7

26

--- 20 (--- 29)

5

21

--- 30 (--- 34)

3

17

MAXIMUM MOISTURE REQUIREMENTS*

VOLUME OF RESIDENCE

TIGHT HOUSE

AVERAGE HOUSE

CUBIC FEET

 

 

 

 

POUNDS

GALLONS (LITERS)

POUNDS

GALLONS (LITERS)

(CUBIC METER)

(KILOGRAMS) PER

PER DAY

(KILOGRAMS) PER

PER DAY

 

 

HOUR

 

HOUR

 

 

 

 

 

 

8,000 (227)

1.76 (0.8)

5.09 (19)

3.52 (1.6)

10.17 (38)

10,000 (283)

2.21 (1.0)

6.35 (24)

4.41 (2.0)

12.72 (48)

12,000 (340)

2.64 (1.2)

7.63 (29)

5.29 (2.4)

15.26 (58)

14,000 (396)

3.09 (1.4)

8.91 (34)

5.92 (2.7)

17.08 (65)

16,000 (453)

3.53 (1.6)

10.18 (39)

7.06 (3.2)

20.35 (77)

18,000 (510)

3.97 (1.8)

11.45 (43)

7.94 (3.6)

22.89 (87)

20,000 (566)

4.41 (2.0)

12.72 (48)

8.82 (4.0)

25.44 (96)

22,000 (623)

4.85 (2.2)

13.99 (53)

9.71 (4.4)

27.98 (106)

24,000 (680)

5.29 (2.4)

15.27 (58)

10.59 (4.8)

30.52 (116)

26,000 (736)

5.74 (2.6)

16.54 (63)

11.47 (5.2)

33.07 (125)

28,000 (793)

6.18 (2.8)

17.81 (67)

12.35 (5.6)

35.61 (135)

30,000 (850)

6.62 (3.0)

19.08 (72)

13.24 (6.0)

38.16 (144)

*Based on design conditions of outdoor 20_F/ ---7_C dry bulb, 80% RH; indoor 70_F/21_C dry bulb, 40% RH, and minimum moisture production from residen- tial operations for an absolute humidity difference of 0.0049 lb/hr.

NOTE:

Tight house is defined as being well insulated, having vapor barriers, tight storm doors and windows with weatherstripping, and having dampered fireplaces. Average house is defined as being insulated, having vapor barriers, loose storm door and windows and having dampered fireplace.

4

Page 4
Image 4
Bryant HUMBBWBP2417, HUMBBLBP2417, HUMBBSBP2412, HUMBBLFP1418 manual Maximum Moisture Requirements