Bryant R-410A warranty 591BN060-A, System Design Summary, CONDENSER ONLY RATINGS* Continued

Models: R-410A

1 28
Download 28 pages 38.92 Kb
Page 25
Image 25

CONDENSER ONLY RATINGS* Continued

 

 

 

 

591BN060-A

 

 

 

 

 

TCG

58.20

55.10

52.00

48.80

45.50

42.10

38.20

33.80

30

SDT

83.60

92.50

101.40

110.40

119.20

127.90

136.40

144.70

 

KW

3.22

3.62

4.06

4.54

5.08

5.63

6.19

6.71

 

 

 

 

 

 

 

 

 

 

 

TCG

63.90

60.40

57.00

53.50

49.90

46.20

42.00

37.40

35

SDT

85.80

94.60

103.40

112.20

120.90

129.50

137.90

146.00

 

KW

3.30

3.70

4.14

4.61

5.15

5.71

6.30

6.87

 

 

 

 

 

 

 

 

 

 

 

TCG

69.80

66.10

62.30

58.40

54.50

50.30

45.90

40.80

40

SDT

88.20

96.80

105.50

114.10

122.60

131.10

139.40

147.30

 

KW

3.38

3.78

4.22

4.69

5.23

5.79

6.39

6.98

 

 

 

 

 

 

 

 

 

 

 

TCG

76.10

71.90

67.80

63.50

59.20

54.60

49.70

44.20

45

SDT

90.60

99.10

107.60

116.10

124.50

132.70

140.80

148.50

 

KW

3.47

3.87

4.31

4.78

5.31

5.87

6.47

7.07

 

 

 

 

 

 

 

 

 

 

 

TCG

82.60

78.10

73.50

68.80

64.00

59.00

53.60

47.50

50

SDT

93.20

101.50

109.80

118.10

126.30

134.40

142.20

149.80

 

KW

3.57

3.97

4.41

4.87

5.40

5.95

6.54

7.14

 

 

 

 

 

 

 

 

 

 

 

TCG

89.40

84.40

79.30

74.20

68.90

63.40

57.40

50.90

55

SDT

95.80

104.00

112.10

120.20

128.20

136.10

143.70

150.90

 

KW

3.67

4.07

4.51

4.97

5.49

6.03

6.61

7.20

 

 

 

 

 

 

 

 

 

 

* ARI listing applies only to systems shown in Ratings and Performance table.

SST

Saturated Temperature Entering Compressor (°F)

kW

Total Power (Kw)

TCG

Gross Cooling Capacity (1000 Btuh).

SDT

Saturated Temperature Leaving Compressor (°F)

 

 

SYSTEM DESIGN SUMMARY

1.Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.

2.Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).

3.Maximum outdoor operating air temperature is 125°F (51.7°C).

4.For reliable operation, unit should be level in all horizontal planes.

5.Maximum elevation of indoor coil above or below base of outdoor unit without additional consideration is: Indoor coil above = 20 ft, indoor coil below = 20 ft. Consult Application Guidelines and Service Manual— Air Conditioners and Heat Pumps Using Puron® Refrigerant prior to application if elevations are exceeded.

6.For interconnecting refrigerant tube lengths greater than 50 ft, consult the Application Guideline and Service Manual— Air Condi- tioners and Heat Pumps Using Puron® Refrigerant Application Guideline and Service Manual— Air Conditioners and Heat Pumps Using Puron® Refrigerant available from equipment distributor.

7.If any refrigerant tubing is buried, provide a 6 in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. may be buried without further consideration. Do not bury lines over 36 in.

8.Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.

9.Do not apply capillary tube indoor coils to these units.

10.Factory-supplied filter drier must be installed. This must be replaced each time the refrigeration system is opened for service.

11.Do not deviate from factory specified TXV’s and Liquid Line Solenoids.

— 25—

Page 25
Image 25
Bryant R-410A warranty 591BN060-A, System Design Summary, CONDENSER ONLY RATINGS* Continued