About Advanced Features & Operation
EMERGENCY HEAT - Is a feature available to Heat Pump installations. To turn on Emergency Heat press in the Fan button. While holding the Fan button press the Up button for 2 seconds. The Cool setpoint display will read ‘EH’.
Press for
Emergency Heat
FAN
12:00:eho
Am73 74HEAT o
During Emergency Heat the thermostat will turn
on the fan and the 2nd stage of heat, when there is a demand for heat, locking out the 1st stage compressor. Exiting Emergency Heat is the same as entering. During Emergency Heat only OFF and HEAT are available.
FACTORY DEFAULTS - If, for any reason it is desirable to return all stored settings back to the factory default settings, press the Mode button. While holding the Mode button in, press the Fan button for 5 sec. All icons will appear. Press and hold in the Fan button until Fd appears. This resets all factory settings. To calibrate room temperature, press the up and down arrow buttons simultaneously, twice..
At this point use the Up or Down buttons to calibrate room temperature, if needed. Press the Mode button to return to normal operation. NOTE CAUTION ON PAGE 1.
Page 15