Bryston Front Panel, Fuses, 875Z - EIGHT CHANNEL POWER AMPLIFIER, POrange LED Thermal Shutdown

Models: 875Z

1 12
Download 12 pages 51.59 Kb
Page 5
Image 5
FRONT PANEL

875Z - EIGHT CHANNEL POWER AMPLIFIER

2

FRONT PANEL of 875Z-Blk

FRONT PANEL

POWER switch

The front panel label '875Z POWER’ is a switch used to apply or remove A/C line power to the 875 soft start circuitry. Push the switch and the 875 will initiate the start up sequence. The switch cap remains indented when circuits are on. Push the switch again the 875 will initiate the power off sequence.

LED Indicators:

Each 875 channel has a single multi-colour LED indicator to monitor the following conditions:

PUnlit LED: no power

The 875 channel LED, when unlit, indicates no A/C mains power is present at the channel. If all channel LED indica tors are unlit the 875 probably needs only to be powered on. A group of 4 LEDs not lighting possibly indicates a blown group fuse. When checking fuses, unplug the power cord. Use only the specified fuses for your operating volt age. See FUSES section below.

PRed LED: muted

Each channel normally mutes momentarily during power up and power down sequences.

PGreen LED: operating normally

PFlashing Red LED: Clipping

Clipping occurs when the channel output level no longer can follow the level increase at the input (Over driven input condition). When a 875 channel is driven into clipping the channel led will change from green to red then back to green when the level is reduced ( Flashing Red ). Momentary clipping can be tolerated, however it indicates that maximum un-distorted power has been surpassed and potential speaker damage may result if over load conditions persist. Any amplifier that is constantly operated into clipping indicates a more powerful amplifier is needed for that application.

POrange LED: Thermal Shutdown

The 875 channel has thermal shutdown circuitry to prevent damage due to over heating. Should thermal shutdown occur, the both stereo channels will mute, and the channel leds will turn orange indicating this condition. When the channels have cooled to a safe operating condition the channels will return to normal operation. Persistent Thermal shutdown indicates steps need to be taken to increase airflow across the channels heat sink.

(Also see installation section on ventilation ).

FUSES

There are two fuse holders located at the front edge of the top panel. When checking fuses, power down the unit and dis- connect the power cord. Use only the specified fuses as indicated on the label located between the two fuse holders on the top panel. See photo at top of page.

2

Page 5
Image 5
Bryston owner manual Front Panel, Fuses, 875Z - EIGHT CHANNEL POWER AMPLIFIER, PGreen LED operating normally