Device Requirements

 

Max. Cord Length (ft) by Wire Gauge

 

Amps

Watts (120V)

Watts (240V)

#8 wire

#10 wire

#12 wire

#14 wire

#16 wire

2.5

300

600

NR

1000

600

375

250

5

600

1200

NR

500

300

200

125

7.5

900

1800

NR

350

200

125

100

10

1200

2400

NR

250

150

100

50

15

1800

3600

NR

150

100

65

NR

20

2400

4800

175

125

75

50

NR

25

3000

6000

150

100

60

NR

NR

30

3600

7200

125

65

NR

NR

NR

40

4800

9600

90

NR

NR

NR

NR

NR = Not Recommended.

Figure 9 - Maximum Extension Cord Lengths by Power Requirement

DC Usage

The DC outlet is only for recharging 12 Volt automotive-type batteries. Do not connect any other device to this outlet.

Use this generator only for recharging 12 Volt batteries. NEVER attempt to jumpstart a car with this generator.

Failing to use the correct procedure can cause a battery to explode, seriously injuring anyone nearby. Keep heat, sparks, flame and smoking materials away from the battery.

To connect 12 Volt batteries to the DC outlet:

1.Connect the red charging wire to the positive terminal of the battery and the black charging wire to the negative terminal of the battery.

2.Connect the plug end of the wire to the 12V DC outlet on this generator.

3.Start this generator.

4.When disconnecting, always disconnect the wires from this generator first to avoid a spark.

Storage batteries emit highly explosive hydrogen gas when charged.

Batteries also contain acid, which can cause severe chemical burns.

Do not allow open flames or cigarettes nearby for several minutes after charging a battery.

Always wear protective goggles and rubber gloves when charging a battery.

If battery acid gets on the skin, flush with water.

If battery acid gets in the eyes, flush with water and immediately call a physician.

If battery acid is swallowed, drink large quantities of milk and immediately call a physician.

STOPPING THE GENERATOR

To stop this generator:

1.Turn off all connected electrical devices and then unplug them.

2.Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator.

3.Turn the engine switch “off”.

4.Turn the fuel valve to the “off” position.

Allow this generator to cool down before touching areas that become hot during operation.