TROUBLESHOOTING
IMPORTANT: If trouble persists, call our customer help line at 
Symptom  | Cause  | Solution  | 
Engine will not start.  | 
  | 
  | 
  | Fuel valve is turned to "closed."  | Turn fuel valve to "open."  | 
  | Choke is open.  | Close the choke.  | 
  | Propane Tank is out of fuel.  | Replace propane fuel tank.  | 
  | 
  | 
  | 
  | Spark plug is dirty.  | Clean spark plug.  | 
  | 
  | 
  | 
  | Generator is not on level surface.  | Move generator to a level surface to prevent  | 
  | 
  | triggering the low oil shutdown.  | 
  | Oil is low.  | Add or replace oil.  | 
Generator runs but does not support all  | Generator is overloaded.  | Reduce draw on generator to within this  | 
connected electrical devices.  | 
  | generator's rated wattage by reducing number  | 
  | 
  | of connected electrical devices.  | 
  | Short in one of the connected devices.  | Disconnect any faulty or   | 
  | 
  | electrical loads.  | 
  | Air filter is dirty.  | Clean or replace air filter.  | 
  | 
  | 
  | 
  | Loose wiring harness connnection  | Turn off generator, then check wiring behind  | 
  | 
  | control panel and at the end of generator for  | 
  | 
  | loose connection. If wires are loose, tighten the  | 
  | 
  | screws and/or nuts. Be certain the plug in  | 
  | 
  | connectors are pushed together all the way.  | 
  | 
  | 
  | 
Engine runs but there is no electrical output.  | Reset button(s) is (are) "off."  | Push reset button(s) to "on."  | 
  | Loose wiring harness connnection  | Turn off generator, then check wiring behind  | 
  | 
  | control panel and at the end of generator for  | 
  | 
  | loose connection. If wires are loose, tighten the  | 
  | 
  | screws and/or nuts. Be certain the plug in  | 
  | 
  | connectors are pushed together all the way.  | 
  | 
  | 
  | 
  | Bad connecting wires/cables.  | Try a different extension cord.  | 
  | Bad electrical device connected to generator.  | Disconnect device, try connecting another  | 
  | 
  | device.  | 
  | 
  | 
  | 
  | 
  | 
  | 
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual  | 23  |