ELECTRICAL REQUIREMENTS
WARNING - The brewer must be disconnected from the power source until specified in Initial
Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.
L2 RED
L2 RED |
L2 RED
L2 RED |
L2 |
WHITEWHITE
NEUTRAL | NEUTRAL |
N
L1 BLACK
L2 |
L1 BLACK
L1
WHITE
NEUTRAL
WHITE
NEUTRAL
N
L1 BLACK | L1 BLACK |
GREEN | GREEN |
L1
G GREEN
GREEN G
L1 BLACK
GREEN
L1 BLACK
L1
GREEN G
120 volt ac models | 200, 208 and 230 volt ac models | 120/208 & 120/240 volt ac models |
Note: This electrical service consists | Note: This electrical service consists | Note: This electrical service consists |
of 2 current carrying conductors (L1 | of 2 current carrying conductors (L1 | of 3 current carrying conductors |
and Neutral) and a separate conduc- | and L2) and a separate conductor | (Neutral, L1 and L2) and a separate |
tor for earth ground. | for earth ground. | conductor for earth ground. |
ELECTRICAL HOOK-UP (Models without power cord)
CAUTION – Improper electrical installation will damage electronic components. Damage caused by incorrect electrical connections is not covered by warranty.
1.An electrician must provide electrical service as specified in conformance with all local, state and federal electrical codes.
2.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3.Remove the front panel beneath the sprayheads to gain access to the terminal block.
4.Feed the cord through the strain relief and connect it to the terminal block.
5.Connect the brewer to the power source and verify the voltage at the terminal block before proceeding. Re- place the front panel.
6.If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing has been hooked up, the brewer is ready for Initial
ELECTRICAL HOOK-UP (Models with power cord)
1.An electrician must provide electrical service as specified in conformance with all local, state and federal electrical codes.
2.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
NOTE - The brewer is shipped without a plug on the power cord. Qualified service personnel must select and install the proper UL listed grounding type attachment plug specified on the rear of the brewer.
3.Install the specified plug on the attached power cord.
4.Remove the front panel beneath the sprayheads to gain access to the terminal block.
5.Connect the brewer to the power source and verify the voltage at the terminal block before proceeding.
6.If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumb- ing has been hooked up, the brewer is ready for Initial
WARNING – Electrical connections must be made as specified above. Failure to follow these instructions can result in personal injury, property or equipment damage.
Page 4