Bunn G9WD-RH service manual Problem, Probable Cause, Remedy, volts AC is present across L1 and

Models: G9WD-RH

1 15
Download 15 pages 42.67 Kb
Page 14
Image 14

TROUBLESHOOTING (Continued)

 

 

 

Problem

Probable Cause

Remedy

Grinder will not start (continued)

5.

Relay

Check that relay contacts close

 

 

 

when start switch is pressed.

 

6.

Motor

With a voltmeter, check that 120

 

 

 

volts AC is present across L1 and

 

 

 

L2 on the rear of the motor when

 

 

 

the Start switch is pressed. If volt-

 

 

 

age is present, and motor does not

 

 

 

start, replace motor.

Grinder will not shut off

1.

STOP button

Use “TEST SWITCHES?” menu un-

 

 

 

der “SERVICE TOOLS?” menu in

 

 

 

level 1 functions to test STOP but-

 

 

 

ton.

 

2.

Relay

With power removed from the ma-

 

 

 

chine, check that there is no conti-

 

 

 

nuity across the relay contacts.

Incorrect weight of coffee dis- pensed

1.Grinder scale requires calibra- tion.

2.Funnel handle touched during grinding.

Refer to GRINDER WEIGHT CALI- BRATION procedure.

Do not touch funnel or funnel han- dle during grinding operation.

14

41451.0001

111909

 

Page 14
Image 14
Bunn G9WD-RH Problem, Probable Cause, Remedy, volts AC is present across L1 and, L2 on the rear of the motor when