INITIAL SET-UP
CAUTION - The dispenser must be disconnected from the power source throughout the initial
1. | Remove the upper rear panel and place the tank heater switch in |
|
| the “OFF” position and replace the panel. |
|
2. | Connect the dispenser to the power source and |
|
| supply. |
|
3. | Water will automatically flow into the tank to the proper level and |
|
|
| |
4. | Disconnect the dispenser from the power source, remove the up- |
|
| per rear panel and place the tank heater switch in the “ON” posi- |
|
| tion, and replace the panel. |
|
5. | Connect the dispenser to the power source and wait approximately |
|
| twenty minutes for the water in the tank to heat. |
|
6. | On models with ready indicator, the indicator will glow when the | P1771 |
| proper water temperature for use is achieved. |
|
NOTE - Discontinue dispensing if the indicator LED turns off. Dispense only when the indicator LED glows.
DRAINING THE DISPENSER
CAUTION - The dispenser must be disconnected from the power source throughout these steps.
1.Disconnect the dispenser from the power source.
2.
3.Remove the
4.Gently remove one of the grommets from the tank lid.
5.Insert a tube to the bottom of the tank and syphon ALL of the water out.
NOTE - The dispenser must be full using the INITIAL
CLEANING
The use of a damp cloth rinsed in any mild,
WALL MOUNTED INSTALLATION
If the dispenser is wall mounted, the bottom of the dispenser should be at the same height as a counter or table top. Use B.O.M. part #12542.0000 for side mounted Wall Bracket Kit or # 13125.0001 for front mounted Wall Bracket Kit .
SUPPORT FOR LARGE RECEPTACLES
CAUTION: If the dispenser is to be used with larger receptacles such as pitchers or pots, those receptacles must be adequately supported during dispensing of hot water to avoid spillage of very hot water. This support may be provided by a table or counter top, or use B.O.M. part #12599.0000 Shelf Kit
5 | 10420 072500 |
|