TROUBLESHOOTING (cont.) |
|
|
|
Problem | Probable Cause | Remedy | |
Water boils continuously. | 1. | Temperature control | Refer to Service – electronic controls for |
|
|
| testing procedures. See page 10. |
| 2. | Lime | Inspect the tank assembliy for excess lime |
|
|
| deposits. Delime as required. |
CAUTION – Tanks and tank components should be delimed reglarly depending on local water conditions. Excessive mineral
Dispenser is making unusual noises.
Ready indicator will not light. (when temperature is within 4° of its selected setting.)
1.Solenoid valve
2.Plumbing lines
3.Water supply
1.Temperature control
2.Ready Indicator LED
The nut on top of the solenoid valve must be tight or it will vibrate during operation.
Plumbing lines should not be resting on the counter top.
(A)The dispenser must be connected to a cold water line.
(B)Water pressure to the dispenser must not be higher than 90 psi (620 kPa). Install a regulator if necessary to lower the work- ing pressure to approximately 50 psi (345 kPa).
Refer to Service – electronic controls for testing procedures. See page 10.
Replace the indicator LED.
8 | 10420 072500 |
|