Bunn JDF-2 manual Refrigeration, Dispenser Locked Out, TROUBLESHOOTING cont PROBLEM, Remedy

Models: JDF-2

1 32
Download 32 pages 63.28 Kb
Page 22
Image 22

TROUBLESHOOTING (cont.)

PROBLEM

Refrigeration

All dispense stations not working or all water & refill LED's flash and beep 3 times.

Note: Cooling failure or excessive bath and cabinet temperatures for m ore than 4 hours will result in touchpad lockout or no dispense.

Dispenser Locked Out

All dispense stations not working or all water & refill LED's flash and beep 3 times.

Hint: Display light goes out during dispenser lockout feature, if the unit has lighted graphics.

Cooling system failure or DBC fault 3.

PROBABLE CAUSE

1.Compressor ON/OFF switch.

2.Dirty condenser filter or fins.

3.Condenser fan not running.

4.Compressor relay not activat- ing.

5.Compressor not running.

6.Compressor running and not cooling.

1.Dispenser lockout password set.

1.Refrigeration or cold water recir- culation system.

REMEDY

Check for "ON" position or no con- tinuity - replace switch.

Clean or replace condenser filter.

Replace fan motor or check fan blades for obstructions.

Check compressor relay coil for 120vac.

NOTE: Aleays check power with coil attached.If no 120vac - replace board. If yes, 120vac - replace relay.

Note: Relay contacts normally open.

Check compressor thermal overload (N/C). If open check for dirty con- denser filter or adequate ventilation and space around machine.

Check refrigeration system for leaks and proper charge.

See page 17 for instruction on how to reset or change password.

Check all previous items that pre- tain to refrigeration or cold water recirculation

22

38310 010406

 

Page 22
Image 22