MENU SCREEN

ACTION

 

 

BIB EMPTY -> 500

Use the (+) or (-) buttons to

(-) EXIT (+)

adjust empty BIB threshold

 

 

XXREFILL -> 155 Use the (+) or (-) buttons to

(-) EXIT (+)

adjust Refill threshold

 

 

 

 

WTR START DELAY

Use the (+) or (-) buttons to

(-) .15SEC (+)

adjust delay time

 

 

 

 

WTR STOP DELAY

Use the (+) or (-) buttons to

(-) .15SEC (+)

adjust delay time

 

 

 

 

TEST LED’S ?

Select (YES) or (NO)

NO EXIT YES

 

 

 

 

 

TEST SWITCHES ?

NONE

UseSwitchToTest

 

 

 

DESCRIPTION

Used to set the Conductance Threshold for the Empty BIB warning. Default is 500

Used to set the Conductance Threshold for the Tank Refill Probe.

Dispense Valve ON Delay. Eliminates weak mix at the beginning of a dispense.

Dispense Valve OFF Delay. Flushes the mix chamber at the end of a dispense.

LED diagnostics. Selecting YES will light all Front Door LED’s.

Switch Diagnostic: Activate switches separately to test. Display will indicate which Switch has been activated. NOTE: Door Interlock switch must be held closed.

TEST REFILL ?

Momentarily depress (YES)

Refill Valve Diagnostic: Press YES to momentarily

 

EXIT YES

 

energize the Solenoid. CAUTION: Inlet Valve will

 

 

 

open and water will flow, if connected and turned

 

 

 

 

 

 

ON.

 

 

 

TEST HEATER ?

Momentarily depress (YES)

Tank Heater Diagnostic: Press YES to momentarily

 

EXIT YES

 

energize the Tank Heater Circuit.

 

 

 

CAUTION: AC power will be applied to the Tank

 

 

 

 

 

 

Heater Circuit.

 

 

 

ENTER ASSET #

Use the (+) or (-) buttons to

Allows the user the option of entering an Asset

(-) 000000 (+)

adjust the ASSET NUMBER

Number. Default is 000000

 

 

 

 

 

 

SERIAL #

NONE

Displays the manufacture’s Serial Number (should

LCR 0000000

 

be identical to the Serial Number on the machine

 

 

 

Data Plate)

 

 

 

 

 

 

FACTORY DEFAULTS

Select (YES) or (NO)

CAUTION: Selecting YES will RESET all

NO

YES

 

Programming Functions to the Factory Default

 

 

 

settings. NOTE: On LCC Models the Chiller will

 

 

 

 

 

 

have to be reset to the ON condition, (see Chilled

 

 

 

Unit programming function).

18