MENU SCREEN

RINSE TIME ? (-) 12 Hrs (+)

RINSE LOCKOUT ?

NO EXIT YES

BIB EMPTY LOCKOUT NO EXIT YES

BREW LOCKOUT ?

NO EXIT YES

DLY REPEAT DISP (-) 0 SEC (+)

ACTION

DESCRIPTION

Use the (+) or (-) buttons to

Enter the desired time between required Rinse

adjust Rinse Alarm delay

Cycles in hours, [8 - 24 hrs.]

Select (YES) to enable

Select YES to Lockout dispensing until the Rinse

 

Alarm has been cleared. Default is NO

Select (YES) to enable

Select YES to Lockout dispensing until the

 

Concentrate BIB has been replaced. Default is

Select (YES) to enable

NO

 

 

Select YES to Lockout dispensing until the hot

Use the (+) or (-) buttons to

water tank is at READY Temp. Default is NO

 

adjust the Delay Time

Enter the desired time delay before allowing the

 

next dispense to take place, [0 - 10 sec.]

The following functions are for diagnostic and troubleshooting purposes and typically do not have to be adjusted. Contact your local service agent for assistance before making changes to these functions.

CAL LEFT SIDE ?

Select (YES) to enable

Selecting Yes will enable the Left Dispenser

EXIT YES

 

Calibration routine, (see Field Calibration before

 

 

attempting to calibrate the dispenser).

 

 

If NO - go to CAL RIGHT SIDE menu.

CAL LEFT PUMP ?

PULL DISPENSE

CAL LF PUMP VOL (-) 43mL (+)

CAL LF WTR FLOW ?

PULL DISPENSER

CAL LF WTR VOL (-) 36.0OZ (+)

CAL LEFT SIDE ? EXIT YES

Place a 50 mL (#34843.1000) graduated cylinder under the Left dispense tip, then activate the Left Dispenser

Use the (+) or (-) buttons to enter volume collected

Place a 64 Oz. (2000 mL) container under the Left dispense tip, then activate the Left Dispenser

Use the (+) or (-) buttons to enter volume collected

NONE

The Left Pump will dispense concentrate for 20 seconds, then shut off automatically. Collect and measure the concentrate dispensed.

Enter the volume of concentrate measured from the Left Pump in mL, (not Oz.) regardless of Preferred Units selected.

The Left Dispenser will dispense hot water for 20 seconds, then shut off automatically. Collect and measure the water dispensed.

Enter the volume of the water measured from the Left dispenser in Oz. (mL).

Scroll down to bypass this screen.

CAL RIGHT SIDE ? EXIT YES

Select (YES) to enable Selecting Yes will enable the Right Dispenser

Calibration routine. Calibration routine, (see Pump Calibration) prior to calibrating the dispenser.

16