MENU SCREEN | ACTION | DESCRIPTION |
|
|
|
TANK TEMP 180 | Use the (+) or | Sets the water Tank temperature [120 - 200°F] |
adjust the target Temp. | or [49 - 93°C] | |
|
|
|
|
|
|
READY TEMP 175 | Use the (+) or | Sets the hot water Ready temperature. Typically |
adjust the target Temp. | set to the minimum desired dispense temp. | |
|
|
|
|
|
|
CABINET TEMP 38 | Use the (+) or | Sets the Chilled Cabinet target temperature [38 |
adjust the target Temp. | - 50°F] or [3 - 10°C] | |
|
|
|
|
|
|
LF PRODUCT DISP | Select (RESET) to clear total | Selecting Reset will clear the Current accumulated |
.0GAL RESET? |
| volume of concentrate dispensed through the Left |
|
| dispenser. Gal (Liters) |
|
| |
|
|
|
LF PRODUCT DISP | NONE | Displays the Total accumulated volume of |
.0GAL |
| concentrate dispensed through the Left dispenser. |
|
| Not |
|
| |
|
|
|
RT PRODUCT DISP | Select (RESET) to clear total | Selecting Reset will clear the Current accumulated |
.0GAL RESET? |
| volume of concentrate dispensed through the |
|
| Right dispenser. Gal (Liters) |
|
| |
|
|
|
RT PRODUCT DISP | NONE | Displays the Total accumulated volume of |
.0GAL |
| concentrate dispensed through the Right |
|
| dispenser. Not |
|
|
The following functions can be Password Protected. If you wish to prevent others from accessing these functions, enter a 4 digit code of your choice. Record your password code [_ _ _ _], as you will need it to access these functions in the future.
| ENTER PASSWORD | Use the (+) or | Enter the access Code to view the remaining | ||
0 | (+) | enter password. | functions. Factory Default = 0. | ||
|
|
|
| ||
|
|
|
| ||
| SET PASSWORD ? | Use the (+) or | Enter your own Code to prevent access to the | ||
0 | (+) | change the password. | remaining functions. [0 to 9999] | ||
|
|
|
| ||
|
|
|
| ||
| SELECT UNITS | Select the preferred units | Used to select the preferred units of measurement. | ||
| ENG | EXIT METRIC |
| (Oz., Gal, deg F) or (mL, L, deg C) | |
|
|
|
| ||
|
|
|
| ||
| CHILLED UNIT ? | Select (YES) or (NO) | LCR Models default to (YES) | ||
| NO | EXIT | YES |
| Select (NO) to turn the refrigeration system |
|
|
|
|
| OFF. |
|
|
|
|
| |
| RINSE ALARM ? |
|
| ||
| NO | EXIT | YES | Select (YES) or (NO) | Selecting Yes will enable the Rinse Alarm function, |
|
|
|
|
| (see Rinse Alarm) |
|
|
|
|
|
If NO - go to BIB EMPTY LOCKOUT menu.
15 | 36026 120105 |
|