PROGRAMMING THE DISPENSER

Remove the lower splash guard assembly to access the digital programming module with LCD display. Press the Down Arrow key to inter the programming menu.

Use the Up and Down Arrow keys to scroll through the menu screens.

Select Exit to leave the programming function and return to normal operations. NOTE 1: Flashing menu items indicate which selection is active.

NOTE 2: Values shown below are the factory default values for English units.

NOTE 3: Values in [X - X] are the Min. and Max. for that function.

MENU SCREEN

ACTION

DESCRIPTION

 

 

 

TANK TEMP XXX

Use the Down Arrow Key

Normal Display for LCR models.

CABINET TEMP XX

to enter Programming

 

 

 

Functions

 

 

 

 

L DISPENSE RATIO

Enter the desired Mix Ratio for the concentrate

 

(-)

35:1 (+)

Use the (+) or (-) buttons to

used in the Left dispenser. [20:1 - 100:1]

 

 

adjust the Mix Ratio

 

 

 

 

SET LF TUBE SIZE

 

Enter Pump Tube Size to be used in the Left

1/8

EXIT 3/16

Select tube size.

metering pump, (see Tube Selection Chart)

 

 

 

 

 

 

R DISPENSE RATIO

 

Enter the desired Mix Ratio for the concentrate

(-)

35:1 (+)

Use the (+) or (-) buttons to

used in the Right dispenser. [20:1 - 100:1]

 

 

adjust the Mix Ratio

 

 

 

 

SET RT TUBE SIZE

Enter Pump Tube Size to be used in the Right

 

1/8

EXIT 3/16

Select tube size.

metering pump, (see Tube Selection Chart)

 

 

 

 

 

 

FLAVOR GUARD ?

Select (YES) to activate.

Select Yes, if you are ready to calibrate the Flavor

NO

EXIT YES

Select (NO) to deactivate.

Guard sensor. Select NO, if you do not wish to

 

 

 

use this feature, (see Flavor Guard)

 

 

 

If NO - go to LF DISP VOLUME menu.

LF TASTE OK ?

Select (YES) or (NO)

Select YES, if you have dispensed several cups

NO

EXIT YES

 

and are satisfied with the Left dispenser flavor.

 

 

 

Select NO, if you have not run taste test.

 

 

 

 

 

 

FIND LF TARGET

Place a 16 Oz. (500 mL)

Calibrates the Left FlavorGard™ sensor to the

PULL

DISPENSE

cup under the Left dispense

current MixProfile. The dispenser will shut OFF

 

 

tip, then activate the Left

automatically when finished.

 

 

 

 

dispenser

 

 

 

 

RT TASTE OK ?

Select (YES) or (NO)

Select YES, if you have dispensed several cups

NO

EXIT YES

 

and are satisfied with the Right dispenser flavor.

 

 

 

Select NO, if you have not run taste test.

 

 

 

 

 

 

FIND RT TARGET

Place a 16 Oz. (500 mL) cup

Calibrates the Right FlavorGard™ sensor to the

PULL

DISPENSE

under the Right dispense

current MixProfile. The dispenser will shut OFF

 

 

tip, then activate the Right

automatically when finished.

 

 

 

 

dispenser

 

13