PROGRAMMING THE DISPENSER
Remove the lower splash guard assembly to access the digital programming module with LCD display. Press the Down Arrow key to inter the programming menu.
Use the Up and Down Arrow keys to scroll through the menu screens.
Select Exit to leave the programming function and return to normal operations. NOTE 1: Flashing menu items indicate which selection is active.
NOTE 2: Values shown below are the factory default values for English units.
NOTE 3: Values in [X - X] are the Min. and Max. for that function.
MENU SCREEN | ACTION | DESCRIPTION | ||
|
|
| ||
TANK TEMP XXX | Use the Down Arrow Key | Normal Display for LCR models. | ||
CABINET TEMP XX | to enter Programming |
| ||
|
| Functions |
| |
|
|
| ||
L DISPENSE RATIO | Enter the desired Mix Ratio for the concentrate | |||
| ||||
35:1 (+) | Use the (+) or | used in the Left dispenser. [20:1 - 100:1] | ||
|
| adjust the Mix Ratio |
| |
|
|
| ||
SET LF TUBE SIZE |
| Enter Pump Tube Size to be used in the Left | ||
1/8 | EXIT 3/16 | Select tube size. | metering pump, (see Tube Selection Chart) | |
|
|
| ||
|
|
| ||
R DISPENSE RATIO |
| Enter the desired Mix Ratio for the concentrate | ||
35:1 (+) | Use the (+) or | used in the Right dispenser. [20:1 - 100:1] | ||
|
| adjust the Mix Ratio |
| |
|
|
| ||
SET RT TUBE SIZE | Enter Pump Tube Size to be used in the Right | |||
| ||||
1/8 | EXIT 3/16 | Select tube size. | metering pump, (see Tube Selection Chart) | |
|
|
| ||
|
|
| ||
FLAVOR GUARD ? | Select (YES) to activate. | Select Yes, if you are ready to calibrate the Flavor | ||
NO | EXIT YES | Select (NO) to deactivate. | Guard sensor. Select NO, if you do not wish to | |
|
|
| use this feature, (see Flavor Guard) | |
|
|
|
If NO - go to LF DISP VOLUME menu.
LF TASTE OK ? | Select (YES) or (NO) | Select YES, if you have dispensed several cups | |
NO | EXIT YES |
| and are satisfied with the Left dispenser flavor. |
|
|
| Select NO, if you have not run taste test. |
|
|
| |
|
|
| |
FIND LF TARGET | Place a 16 Oz. (500 mL) | Calibrates the Left FlavorGard™ sensor to the | |
PULL | DISPENSE | cup under the Left dispense | current MixProfile. The dispenser will shut OFF |
|
| tip, then activate the Left | automatically when finished. |
|
| ||
|
| dispenser |
|
|
|
| |
RT TASTE OK ? | Select (YES) or (NO) | Select YES, if you have dispensed several cups | |
NO | EXIT YES |
| and are satisfied with the Right dispenser flavor. |
|
|
| Select NO, if you have not run taste test. |
|
|
| |
|
|
| |
FIND RT TARGET | Place a 16 Oz. (500 mL) cup | Calibrates the Right FlavorGard™ sensor to the | |
PULL | DISPENSE | under the Right dispense | current MixProfile. The dispenser will shut OFF |
|
| tip, then activate the Right | automatically when finished. |
|
| ||
|
| dispenser |
|
13 | 36026 042104 |
|