MENU SCREEN | ACTION | DESCRIPTION |
If NO - skip to next menu.
CAL RIGHT PUMP ?
PULL DISPENSER
CAL RT PUMP VOL
CAL RT WTR FLOW
PULL DISPENSER
CAL RT WTR VOL
CAL RIGHT SIDE ? EXIT YES
Place a 50 mL (#34843.1000) graduated cylinder under the Right dispense tip, then activate the Right Dispenser
Use the (+) or
Place a 64 Oz. (2000 mL) container under the Right dispense tip, then activate the Right Dispenser
Use the (+) or
NONE
The Right Pump will dispense concentrate for 20 seconds, then shut off automatically. Collect and measure the concentrate dispensed.
Enter the volume of concentrate measured from the Right Pump in mL(not Oz.) regardless of Preferred Units selected.
The Right Dispenser will dispense hot water for 20 seconds, then shut off automatically. Collect and measure the water dispensed.
Enter the volume of the water measured from the Right dispenser in Oz. (mL)
Scroll down to bypass this screen.
For Portion Control Dispensers
CAL HOT WTR FLO ?
PULL DISPENSE
CAL HOT WTR VOL
XXXCAL
FlvrGrdRange 10%
LfFlvrGrdTargets
RPM
RtFlvrGrdTargets
RPM
Place a 64 Oz. (2000 mL) container under the Hot Water dispense tip, then activate the Hot Water Dispenser
Use the (+) or
Use the (+) or
Use the (+) or
NONE
NONE
The Hot Water Dispenser will dispense for 20 seconds, then shut off automatically. Collect and measure the water dispensed.
Enter the volume of the water measured from the Hot Water Dispenser in Oz. (mL)
Adjust the display reading to match a calibrated probe inserted next to the Tank Sensor, °F (°C).
Used to set the maximum adjustment the Flavor Guard feature is allowed to make, [3 - 15%].
Displays the Left Dispenser target RPM and Conductance Reading, (Diagnostics Only)
Displays the Right Dispenser target RPM and Conductance Reading, (Diagnostics Only)
17 | 36026 120105 |
|