TROUBLESHOOTING (cont.)

PROBLEM

Spitting or excessive steaming

PROBABLE CAUSE

1. Lime Build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks.

REMEDY

Inspect tank assembly for excessive lime deposits. Delime as required.

2. Control Thermostat

Drip-out time too long

1. Funnel Tip

Refer to Service - Control Thermo- stat for testing procedures. See page 20

The brew funnel should be cleaned thoroughly before each brew cycle to lessen the chance of tea leaf par- ticles clogging the drip-out tip.

Dripping from sprayhead

1.

Syphon System

 

2.

Lime Build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks.

The brewer must be level or slightly lower in front to syphon properly.

Inspect the tank assembly for ex- cessive lime deposits. Delime as required.

3. Brew Solenoid Valve

Water flows into tank continuously

1. Brew Timer

(ON/OFF or Slector Switch "ON")

 

Water flows into tank continuously

1. Brew Solenoid Valve

(ON/OFF or Selector Switch "OFF")

 

Refer to Service - Brew Solenoid Valve for testing procedures. See page 15

Refer to Service - Brew Timer for testing procedures. See page 17 or 18

Refer to Service - Brew Solenoid Valve for testing procedures. See page 15

Page 11